£105.46 AHP-3742
Description
Click on this link if you need more information about Industrial Heaters.Model Number |
‡Voltage V |
Power Watts |
Heated Length mm |
†Watts/ 25 mm |
Maximum Flow litres/min |
Diameter mm |
Cross Sectional Flow Area mm² |
Process Fittings NPT |
Weight g |
AHP-3742 | 120 | 50 | 89 | 14 | 226 | 9.5 | 19.35 | 1/4' | 82 |
240 | 200 | 57 | |||||||
AHP-5052 | 120 | 100 | 114 | 22 | 283 | 12.7 | 23.23 | 3/8' | 113 |
240 | 400 | 88 | |||||||
AHP-7562 | 120 | 190 | 140 | 34 | 567 | 19.1 | 81.29 | 3/4' | 308 |
240 | 750 | 134 |
Minimum Air Flow Required. litres/min |
Maximum Power (W) | ||
AHP-3742 | AHP-5052 | AHP-7562 | |
29 | 60 | 80 | 120 |
57 | 60 | 80 | 120 |
114 | 100 | 100 | 120 |
170 | 150 | 150 | 150 |
227 | 200 | 200 | 200 |
284 | - | 250 | 250 |
425 | - | - | 375 |
567 | - | - | 500 |
Model | D | Heated Length LH | L ±1.6 | A Nom. | B Nom. |
AHP-3742 | 9.5 | 89 | 101.6 | 33.3 | 7.9 |
AHP-5052 | 12.7 | 114 | 127.0 | 34.9 | 19.0 |
AHP-7562 | 19.1 | 140 | 152.4 | 61.9 | 41.3 |