Water Treatment Controllers

CDCN Series

Water Treatment Controllers | CDCN Series

Water Treatment Controllers

  • Digital Conductivity Display and Control
  • Temperature Display
  • Three Chemical Feed Programs (Conductivity, pH and Additive)
  • Langelier Saturation Index for Water Balance
  • Chemical Level Alarm
  • Integral Data Logging for up to 999 Points With RS232 Communications
  • Time-Based Chemical Level Alarm
  • NEMA 4X Wall Mount Enclosure
  • Remote Computer Operation with Windows Software

Description

The CDCN10 Series is specifically designed to measure conductivity/dissolved solids and pH in cooling towers, boilers, industrial process water, food processing, drinking water and wastewater treatment applications. The CDCN10 Series conductivity/pH controllers are highly accurate and easy to install and operate. Engineering units can be displayed in either US or metric values using the pushbutton keypad and the simple scroll-through menus. Both units control conductivity, with the ability to control 3 additive feed programs. You can get a readout of the probe temperature. pH measurement and control is optional on both units, as is a safety flow switch contact, and RS485 communications.

The CDCN12 has additional features over the standard CDCN11, including dynamic probe failure testing for pH/ORP sensors, allowing the controller to detect a probe failure quickly after it occurs, so the user can avoid dangerous out-of-range conditions. For convenience, the CDCN12 features a large 4-line LCD readout and 16-button keypad.

SPECIFICATIONS
Measurement Range:
Conductivity: 0 to 20,000 µS/cm or ppm; conversion factor for TDS
pH: 0 to 14 pH; setpoint for acid or base feed
Accuracy:
    Conductivity: ±1% rdg
    pH: ±0.1 pH
Resolution:
    Conductivity: 1µS
    pH: 0.01 pH
Temperature Range: -18 to 60°C (0 to140°F)
Watermeter Input: For totalizer function, CDCN11 only
Sensor Calibration: 1, 2 or 3 points
Control Modes: Off, manual, auto, timer, bleed and feed, bleed-then-feed, daily schedule
Langelier Index: Water balance display calculated from pH, temp, total alkalinity and calcium hardness
Alarms: High/low, out-of-range, overfeed and total run time; visual, audible and external (5 A) alarms
Data Logging: On-board memory for 999 tests; RS232 communication port for local download and printing
Networking: RS485 port for multiple connections (optional)
Remote Operation: Software and graphical display for Windows®
Power: 115/230 Vac, 10 A
Control Outputs: 5 A relays, SPST
    CDCN11 Relays: 3 additive, one alarm, one bleed
    CDCN12 Relays: 2 additive, one additive/alarm (selectable), one bleed
Probe Sensor Failure: CDCN12 only, for pH/ORP electrode
Display:
    CDCN11: One line LCD; 5-button keypad
    CDCN12: Four line LCD; 16-button keypad
Mechanical: NEMA 4X enclosure
Dimensions:
    CDCN11: 240 x 190 x 90 mm (9.5 x 7.5 x 3.5")
    CDCN12: 285 x 234 x 155 mm (11.21 x 9.21 x 6.09")
Shipping Weight:
    CDCN11: 2.7 kg (6 lb)
    CDCN12: 6.0 kg (13 lb)
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
CDCN11
Consult Sales  
Availability: 
 
 
Conductivity inputs, RS232 communications, 5-button Keypad, one line display
CDCN11-PH
Consult Sales  
Availability: 
 
 
Conductivity/pH inputs, RS232 communications, 5-button Keypad, one line display
CDCN11-485
Consult Sales  
Availability: 
 
 
Conductivity inputs, RS232/RS485 communications, 5-button Keypad, one line display
CDCN11-PH-485
Consult Sales  
Availability: 
 
 
Conductivity/pH inputs, RS232/RS485 communications, 5-button Keypad, one line display
CDCN12
Consult Sales  
Availability: 
 
 
Conductivity inputs, RS232 communications, 16-button Keypad, four line display
CDCN12-PH
Consult Sales  
Availability: 
 
 
Conductivity/pH inputs, RS232 communications, 16-button Keypad, four line display
CDCN12-485
Consult Sales  
Availability: 
 
 
Conductivity inputs, RS232/RS485 communications, 16-button Keypad, four line display
CDCN12-PH-485
Consult Sales  
Availability: 
 
 
Conductivity/pH inputs, RS232/RS485 communications, 16-button Keypad, four line display
Accessories
CDE10
Consult Sales  
Availability: 
 
 
Conductivity sensor
CDE10HP
Consult Sales  
Availability: 
 
 
High pressure conductivity sensor
PHE10
Consult Sales  
Availability: 
 
 
pH electrode
PHE10HP
Consult Sales  
Availability: 
 
 
High pressure pH electrode
FSW10S
Consult Sales  
Availability: 
 
 
Shuttle style flow switch
FSW10B
Consult Sales  
Availability: 
 
 
Blade style flow switch
Recommended pH Solutions
PHA-4
£13.58
Availability: In Stock
 
4.00 pH buffer solution, 500 mL (1 pt) bottle
PHA-7
£13.58
Availability: In Stock
 
7.00 pH buffer solution, 500 mL (1 pt) bottle
PHA-10
£13.58
Availability: In Stock
 
10.00 pH buffer solution, 500 mL (1 pt) bottle
Recommended Conductivity Solutions
CDSA-45
£14.68
Availability: 2 weeks
 
45 µmho/cm conductivity solution, 946 mL (1 qt)
CDSA-1413
£32.45
Availability: 2 weeks
 
1413 µmho/cm conductivity solution, 946 mL (1 qt)
CDSA-1500
£14.68
Availability: 2 weeks
 
1500 µmho/cm conductivity solution, 946 mL (1 qt)
All amounts shown in EUR, GBP, or USD
Note: Comes complete with operator’s manual and 3V lithium battery. Probes sold separately.
When ordering the conductivty or pH controller, it is recommended to purchase pH buffer solution, such as PHA-7, pH buffer 7 and conductivity standard solution.
We noticed you are from the US. Visit your local site for regional offers and live support.