Cookies on the OMEGA websites
We use cookies on this website, these cookies are essential for the website to work correctly.If you continue without changing your settings, we'll assume that you are happy to receive all cookies on this website.To find out more information about these cookies please click here.
CLOSE
Basket  |  Contact  |  Help  | 
Free Phone 0800 488 488
International+44(0) 161 777 6611
Layer N Banner

Water Treatment Controllers

CDCN Series

Water Treatment Controllers | CDCN Series

Water Treatment Controllers

  • Digital Conductivity Display and Control
  • Temperature Display
  • Three Chemical Feed Programs (Conductivity, pH and Additive)
  • Langelier Saturation Index for Water Balance
  • Chemical Level Alarm
  • Integral Data Logging for up to 999 Points With RS232 Communications
  • Time-Based Chemical Level Alarm
  • NEMA 4X Wall Mount Enclosure
  • Remote Computer Operation with Windows Software

Description

The CDCN10 Series is specifically designed to measure conductivity/dissolved solids and pH in cooling towers, boilers, industrial process water, food processing, drinking water and wastewater treatment applications. The CDCN10 Series conductivity/pH controllers are highly accurate and easy to install and operate. Engineering units can be displayed in either US or metric values using the pushbutton keypad and the simple scroll-through menus. Both units control conductivity, with the ability to control 3 additive feed programs. You can get a readout of the probe temperature. pH measurement and control is optional on both units, as is a safety flow switch contact, and RS485 communications.

The CDCN12 has additional features over the standard CDCN11, including dynamic probe failure testing for pH/ORP sensors, allowing the controller to detect a probe failure quickly after it occurs, so the user can avoid dangerous out-of-range conditions. For convenience, the CDCN12 features a large 4-line LCD readout and 16-button keypad.

SPECIFICATIONS
Measurement Range:
Conductivity: 0 to 20,000 µS/cm or ppm; conversion factor for TDS
pH: 0 to 14 pH; setpoint for acid or base feed
Accuracy:
    Conductivity: ±1% rdg
    pH: ±0.1 pH
Resolution:
    Conductivity: 1µS
    pH: 0.01 pH
Temperature Range: -18 to 60°C (0 to140°F)
Watermeter Input: For totalizer function, CDCN11 only
Sensor Calibration: 1, 2 or 3 points
Control Modes: Off, manual, auto, timer, bleed and feed, bleed-then-feed, daily schedule
Langelier Index: Water balance display calculated from pH, temp, total alkalinity and calcium hardness
Alarms: High/low, out-of-range, overfeed and total run time; visual, audible and external (5 A) alarms
Data Logging: On-board memory for 999 tests; RS232 communication port for local download and printing
Networking: RS485 port for multiple connections (optional)
Remote Operation: Software and graphical display for Windows®
Power: 115/230 Vac, 10 A
Control Outputs: 5 A relays, SPST
    CDCN11 Relays: 3 additive, one alarm, one bleed
    CDCN12 Relays: 2 additive, one additive/alarm (selectable), one bleed
Probe Sensor Failure: CDCN12 only, for pH/ORP electrode
Display:
    CDCN11: One line LCD; 5-button keypad
    CDCN12: Four line LCD; 16-button keypad
Mechanical: NEMA 4X enclosure
Dimensions:
    CDCN11: 240 x 190 x 90 mm (9.5 x 7.5 x 3.5")
    CDCN12: 285 x 234 x 155 mm (11.21 x 9.21 x 6.09")
Shipping Weight:
    CDCN11: 2.7 kg (6 lb)
    CDCN12: 6.0 kg (13 lb)
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
CDCN11
Consult Sales  
Availability: 
 
 
Conductivity inputs, RS232 communications, 5-button Keypad, one line display
CDCN11-PH
Consult Sales  
Availability: 
 
 
Conductivity/pH inputs, RS232 communications, 5-button Keypad, one line display
CDCN11-485
Consult Sales  
Availability: 
 
 
Conductivity inputs, RS232/RS485 communications, 5-button Keypad, one line display
CDCN11-PH-485
Consult Sales  
Availability: 
 
 
Conductivity/pH inputs, RS232/RS485 communications, 5-button Keypad, one line display
CDCN12
Consult Sales  
Availability: 
 
 
Conductivity inputs, RS232 communications, 16-button Keypad, four line display
CDCN12-PH
Consult Sales  
Availability: 
 
 
Conductivity/pH inputs, RS232 communications, 16-button Keypad, four line display
CDCN12-485
Consult Sales  
Availability: 
 
 
Conductivity inputs, RS232/RS485 communications, 16-button Keypad, four line display
CDCN12-PH-485
Consult Sales  
Availability: 
 
 
Conductivity/pH inputs, RS232/RS485 communications, 16-button Keypad, four line display
Accessories
CDE10
Consult Sales  
Availability: 
 
 
Conductivity sensor
CDE10HP
Consult Sales  
Availability: 
 
 
High pressure conductivity sensor
PHE10
Consult Sales  
Availability: 
 
 
pH electrode
PHE10HP
Consult Sales  
Availability: 
 
 
High pressure pH electrode
FSW10S
Consult Sales  
Availability: 
 
 
Shuttle style flow switch
FSW10B
Consult Sales  
Availability: 
 
 
Blade style flow switch
Recommended pH Solutions
PHA-4
£13.58
Availability: 2 weeks
 
4.00 pH buffer solution, 500 mL (1 pt) bottle
PHA-7
£13.58
Availability: In Stock
 
7.00 pH buffer solution, 500 mL (1 pt) bottle
PHA-10
£13.58
Availability: In Stock
 
10.00 pH buffer solution, 500 mL (1 pt) bottle
Recommended Conductivity Solutions
CDSA-45
£14.68
Availability: 2 weeks
 
45 µmho/cm conductivity solution, 946 mL (1 qt)
CDSA-1413
£32.45
Availability: 2 weeks
 
1413 µmho/cm conductivity solution, 946 mL (1 qt)
CDSA-1500
£14.68
Availability: 2 weeks
 
1500 µmho/cm conductivity solution, 946 mL (1 qt)
All amounts shown in EUR, GBP, or USD
Note: Comes complete with operator’s manual and 3V lithium battery. Probes sold separately.
When ordering the conductivty or pH controller, it is recommended to purchase pH buffer solution, such as PHA-7, pH buffer 7 and conductivity standard solution.
We noticed you are from the US. Visit your local site for regional offers and live support.