1/4 DIN Temperature/Process Ramp/Soak Profile Controller with Alphanumeric Message Display
Discontinued Product!

Currency: 

CN1462

1/4 DIN Temperature/Process Ramp/Soak Profile Controller with Alphanumeric Message DisplayDiscontinued Product! | CN1462

CE
  • Universal Sensor Inputs: Thermocouple, 3-Wire RTD or DC Linear (mA, mV or V)
  • Autotune on Soaks and Basic Process Control
  • Remote and Local Program Number Select, Run, Hold, and Abort
  • 90 to 264 Vac Power Supply
  • Dual 4-Digit Programmable Display and Alphanumeric Message Display
  • End of Program Relay Output
  • Eight Programs, 16 Segments with Program Joining
  • Readable Run Time Messages
  • Assured Soak
  • NEMA-4/IP65 Sealed Front Panel

    Optional Features
  • Low Voltage Power Supply: 20 to 50 Vac/ 22 to 65 Vdc
  • RS-485 Communications
  • Remote Inputs, Event Outputs
  • Real Time Clock

Description



TheCN1460 Series is no longer available. Please see the CN8240/ CN8260 Series as a substitute or contact Sales/Temperature Engineering.

The OMEGA™ CN1462 is a 1/4 DIN microprocessor-based, single loop process controller with programmable setpoint profile programs. It can function either as a basic process controller, utilizing manual setpoint changes, or it can execute any one of eight setpoint programs. Each program is adjustable in the range of 1 to 16 segments, cascadable to a maximum length of 121 segments. Each segment can be a ramp, a soak, a join, or an end. A delayed start feature is standard, as is an end of program relay. By using the auto hold feature, assured soaks are possible. The unit can include two 4-20 mA current outputs which can be used for control and a third current output to be used for retransmission. In lieu of current control outputs, relays or dc pulse outputs are available. Four (4) relay event outputs are available as an option. The CN1462 is used to control or program temperature or other process variables in a variety of applications.

Examples of pricing for popular models is referenced in the "To Order" box. Use the "Part Number Builder" below to get pricing for all available models.
For complete product specifications see the Related Links section at the bottom of this page.
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
CN1462-DC1-4
Consult Sales  
Availability: 
 
 
Ramp/soak profile controller with dc pulse output and real time clock
CN1462-R1-DC2-XP3
Consult Sales  
Availability: 
 
 
Ramp/soak profile controller with relay output and excitation power
CN1462-R1-R2-DC3-LV-C4
Consult Sales  
Availability: 
 
 
Ramp/soak profile controller with two relay outputs, dc pulse output, 20-50 Vac/22-65 Vdc power, 20-27 Vdc excitation power and RS-485 communications
CN1462-R1-R2-XP3-LV-C4
Consult Sales  
Availability: 
 
 
Ramp/soak profile controller with two relay outputs, 20-27 Vdc excitation power, 20-50 Vac/22-65 Vdc power, and RS-485 communications
BD1600-R
Consult Sales  
Availability: 
 
 
Field Installable 2 A relay board
BD1600-DC
Consult Sales  
Availability: 
 
 
Field Installable dc pulse output board
BD1600-F
Consult Sales  
Availability: 
 
 
Field Installable analog output board
BD1600-C4
Consult Sales  
Availability: 
 
 
Field Installable RS-485 Communications board
BD1600-XP
Consult Sales  
Availability: 
 
 
Field Installable transmitter power supply board
All amounts shown in EUR, GBP, or USD
Note: The single output models are standard. To order two or three outputs, specify output suffix from the Second and Third Output Options tables.

Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Base Models select from:
CN1462-R1 for Single relay output profile controller
CN1462-DC1 for Single dc pulse output profile controller
CN1462-F1 for Single analog output profile controller

(2) Second Output Options select from:
Nothing(leave field blank) for Standard Unit
-R2 for Relay
-DC2 for dc pulse
-F2 for Analog (control only)
-XP2 for Transmitter power supply

(3) Third Output Options select from:
Nothing(leave field blank) for Standard Unit
-R3 for Relay
-DC3 for dc pulse
-F3 for Analog (retransmission only)
-XP3 for Transmitter power supply

(4) Low Voltage Power Supply Option select from:
Nothing(leave field blank) for Standard Unit
-LV for 20 to 50 Vac / 22 to 65 Vdc

(5) RS-485 Communications Option select from:
Nothing(leave field blank) for Standard Unit
-C4 for RS-485 communications

(6) Additional Options (Only 1 option available per unit) select from:
Nothing(leave field blank) for Standard Unit
-1 for 4 event outputs
-2 for 6 remote profile control inputs
-3 for 4 event outputs and 6 remote profile control
-4 for Real time clock
-5 for Real time clock and event outputs
-6 for Real time clock and event inputs
-7 for Real time clock and event outputs and
Note: All combinations may not be valid, check spec sheet for valid part numbers.