Cookies on the OMEGA websites We use cookies on this website, these cookies are essential for the website to work correctly.If you continue without changing your settings, we'll assume that you are happy to receive all cookies on this website.To find out more information about these cookies please click here.
An additional programming tool is available the Omega Google App - Direct Link relying on RFID/NFC connectivity and allowing straightforward programming without additional wiring and programmable via Android devices.
Description
The CN400 Single/Dual Inputs PID Controller Series stand out for the bright display which ensures optimal visibility and increased level of information for the operator. The CN400 Series introduces the latest NFC/RFID programming technology with a dedicated App - Omega Direct Link for all Android devices (Free Download from Google Play). No more wiring, cables, or power supply, just quick set-up/updates on site with your phone. With dual analog input and dual analog outputs model option, the CN400 Series can achieve two separate heating/cooling PID control loops in one device or to handle mathematical operations between two process values. The outputs can be selected as command/multiple alarm modes/analog retransmission. Serial communication standard is RS485 with Modbus RTU/Slave protocol. The CN400 Series power supply has an extended range of 24 to 230VAC / VDC with galvanic insulation of the net for the single loop version, while the model with double analog input provides two versions: 115 / 230 VAC or 24 VAC / VDC.
Specifications
Inputs 1 or 2 - Configurable: 16 bit, selectable for TC type K, S, R, J, T, N, B (automatic compensation of cold junction) -25 to 85°C, ±0,2% F.S. ±1 digit F.S.), thermoresistances PT100, PT500, PT1000, Ni100, PTC1K, NTC10K (β 3435K), process signals 0 to 10 V (50000 points), 0/4 to 20mA (40000 points), 0 to 60 mV (25000 points), potentiometer 1 to 150 KΩ (50000 points) Sampling time: Programmable up to 2.1 ms (frequency up to 470 Hz) 2/4 digital inputs: Setpoint change, Hold, Run, Tuning launch, Start / Stop, Lock configuration 1 Current Transformer (C.T.) input: Selection C.T. 50 mA, 800 μs - 4096 points
Outputs 2/3 relays: Relay 2 A - 250 V AC resistive change 2 SSR: 12 / 24 V DC - 30 mA max 1/2 analog: Selection 4 to 20 mA (40000 points ± 0,2% F.S.) or 0 to 10 V DC (40000 points ± 0,2% F.S.) for command or retransmission PV / SPV Serial communication: RS485 Modbus RTU - Slave (4800 to 115200 baud code-T)
Software Features Control algorithms: ON - OFF with hysteresis, P., P.I., P.I.D., P.D. time proportional Tuning: Manual or automatic Data protection: Lock of control / alarm setpoint / Access to parameters by password Alarm modes: Absolute / Threshold, Band, High / Low deviation. Alarm with optional Manual reset. Loop Break Alarm Auto / Manual function: Output percentage command also with automatic change in case of sensor failure Double P.I.D: Heating / Cooling P.I.D Programmer function: Pre-programmed cycle / 3 steps Soft-Start: Rising gradient expressed as Degrees / Hour or fixed output percentage Open / Close logic: Open / Close logic for motorized valves
Box: 48 x 48 (front panel) x 105 mm Power supply: 24 to 230 V AC / DC ±15% 50/60 Hz - galvanic isolation 2.5KV Consumption: 8 W Display: 4 digits 0.5” white + 4 digits 0.3” red Operating conditions: Temperature 0 to 45 °C, humidity 35 to 95 RH% MaterialBox: PC UL94V2 self-extinguishing, front panel: PC UL94V2 Weight: Approx. 185 g Sealing: IP65 (front panel) IP20 (box and terminal blocks) Quick set-up options: Memory Card, software LABSOFTVIEW, or EASY-UP APP: NFC Programming via APP Direct Link for Android smartphones