Cookies on the OMEGA websites We use cookies on this website, these cookies are essential for the website to work correctly.If you continue without changing your settings, we'll assume that you are happy to receive all cookies on this website.To find out more information about these cookies please click here.
SPECIFICATIONS Power: 115/230 Vac, user-selectable; 50 to 60 Hz; preset to 115 Vac Power Consumption: 3 VA Output 1: SPDT mechanical relay, rated 5 A at 250 Vac, resistive load Output 2: SPDT mechanical relay, rated 3 A at 250 Vac, resistive load Setpoint 1: front dial adjustment Setpoint 2: screwdriver adjustment within ±10% of temperature range relative to setpoint 1 Accuracy: 2% FS, within 5 to 95% or range Accuracy Reference Conditions: 22°C ±2°C (72°F ±3.6°F), after 30 min. warm-up time Proportional Band: 3% FS fixed Cycle Time: 25 s, nominal, fixed On-Off Deadband: 2% FS, Fixed Input Types: J, K, T, R, S thermocouples; 100 ohm Pt RTD, 2- or 3-wire Sensor Burnout: upscale, automatic Common Mode: negligible effect to 264 Vrms, 50/60 Hz Normal Mode: negligible effect to full scale mV, 50/60 Hz Ambient Temperature Range: to 50°C (32 to 130°F) Dimensions: 48 H x 48 W x 97 mm D (1.89 x 1.89 x 3.8") Panel Cutout: 45 mm (1.772") square Weight: 250 g (9 oz)
Examples of pricing for popular models is referenced in the "To Order" box. Use the "Part Number Builder" below to get pricing for all available models.
† All amounts shown in EUR, GBP, or USD Note: CN873 and CN883 Panel Mount with Push-On Connectors (supplied). CN872, CN874, CN882 and CN884 Plug-in or Panel Mount with Socket Mount Design. Mating Socket and Push-on Connectors Included.
Part Number Builder
Build Your Part Number Below
Option Descriptions:
(1)
Output select from: CN872 for Proportional on Output 1 & No Output 2 (Socket Connection) CN873 for Proportional on Output 1 & No Output 2 (Push-On Connection) CN874 for Proportional on Output 1 & On-Off on Output 2 (Socket Connection) CN882 for On-Off on Output 1 & No Output 2 (Socket Connection) CN883 for On-Off on Output 1 & No Output 2 (Push-On Connection) CN884 for On-Off on Output 1 & On-Off on Output 2 (Socket Connection)
(2)
Input Type & Range select from: J-200F for J 0 to 200 F J-300F for J 0 to 300 F J-300C for J 0 to 300 C J-500F for J 0 to 500 F J-1200F for J 0 to 1200 F K-500F for K 0 to 500 F K-1200F for K 0 to 1200 F K-1200C for K 0 to 1200 C T-NF for T -100 to 200 F T-NC for T -100 to 200 C T-300C for T 0 to 300 C R-1600C for R 0 to 1600 C S-1600C for S 0 to 1600 C RTD-NC for RTD -100 to 200 C RTD-500C for RTD 0 to 500 C
Note: All combinations may not be valid, check spec sheet for valid part numbers.