Cookies on the OMEGA websites We use cookies on this website, these cookies are essential for the website to work correctly.If you continue without changing your settings, we'll assume that you are happy to receive all cookies on this website.To find out more information about these cookies please click here.
4 V (300 Vdc Max) and 5 Current (2A dc Max) Ranges
3 Resistance Ranges - 10 KÙ Max
Field-Upgradeable Option Cards
AC and DC Powered Versions
NEMA 4X (IP65)
Description
The DP63600 series has been discontinued. Please see the Platinum Series as a possible alternative or contact our sales department.
The DP63600 Series panel meters
offer many features and
performance capabilities suitable for
a wide range of industrial
applications. These meters accept
universal DC voltage/current inputs.
The optional plug-in output cards
allow the opportunity to configure
the meter for present applications,
while providing easy upgrades for
future needs.
The meters employ a bright, 14 mm
(0.56") LED display. The unit is
available with a red sunlight
readable or a standard green LED.
The intensity of display can be
adjusted from dark room to sunlight
readable, making it ideal for viewing
in variable light applications.
The meters provide a max and min
reading memory with programmable
capture time. The capture time is
used to prevent detection of false
max or min readings which may
occur during start-up or unusual
process events.
The meters have 4 setpoint outputs,
implemented on plug-in option
cards.The plug-in cards provide
dual form “C” relays (5A), quad
form “A” (3A), or either quad-sinking
or quad-sourcing open collector
logic outputs. The setpoint alarms
can be configured to suit a variety
of control and alarm requirements.
Communication and bus capabilities
are also available as option cards;
these include RS232, RS485, and
MODBUS.
† All amounts shown in EUR, GBP, or USD Note: *Software is free. Download from omega.com Comes with complete operator’s manual. Note: Adding option cards—meters can be fitted with up to 3 optional plug-in cards, however, only 1 card from each function type can be installed at a time. The function types include setpoint alarms, analog output and communications. The cards can be installed initially or at a later date. Each optional plug-in card is shipped with installation and programming instructions. Ordering Example: (1) LDP6-CDL10 analog output card, £116.92