Cookies on the OMEGA websites We use cookies on this website, these cookies are essential for the website to work correctly.If you continue without changing your settings, we'll assume that you are happy to receive all cookies on this website.To find out more information about these cookies please click here.
Application
• Fast < 20 ms response time for measuring signals produced
by torque, position, current & acceleration sensors.
• User configurable bipolar or unipolar I/O means the DRST-DC is
suitable for nearly any DC voltage or current conversion.
• Freely programmable between ±300 VDC and ±100 mA.
The excitation source allows measurement of a 2-wire or 3-wire transmitter, or a potentiometer.
• Converts narrow bipolar inputs to wide bipolar or unipolar
outputs, e.g., ± 1 volt input = ± 10 volt or 4 to 20 mA output.
• Configurable input limits control the output value for increased
safety.
• ±20 VDC buffered voltage output for controlling devices like
the PVG 32 valve (6 to 18 VDC).
Technical Characteristics
• The latest analog and digital techniques are used to obtain maximum accuracy and immunity to interference.
• Possibility of output safety read back by selecting 4 to 20 mA
output.
• The current output can drive up to 1000 Ω, with an
adjustable response time of 0.0…60.0 seconds.
• Exceptional mA output load stability of < 0.001% of span/100
Ω.
• Meets the NAMUR NE21 recommendations, ensuring high accuracy in harsh EMC environments.
• Meets the NAMUR NE43 recommendations, allowing the control system to easily detect a sensor error.
• Each unit is tested to a high 2.3 kVAC, 3-port galvanic
isolation level.
• Excellent signal to noise ratio of > 60 dB. Mounting/Installation/Programming
• Very low power consumption means units can be mounted
side by side without an air gap – even at 60°C (140ºF) ambient temperature.
• Configuration, monitoring, 2-point process calibration and more are accomplished using either the DRSL-Display detachable display or the DRST-CM detachable digital communication enabler.
• All programming can be password-protected.
Specifications Environmental Conditions Operating Temperature: -20 to 60°C Storage Temperature: -20 to 85°C Calibration Temperature: 20 to 28°C Relative Humidity: < 95% RH (non-cond.) Protection degree: IP20 Mechanical Specifications Dimensions (H x W x D): 109 x 23.5 x 104 mm Dimensions (H x W x D) with 4501/4511: 109 x 23.5 x 116/131 mm Weight Approx: 250 g Weight Incl. 4501/4511 (approx.): 285 g/350 g
DIN Rail Type: DIN EN 60715/35 mm Wire Size: 0.13 to 2.08 mm2 AWG 26 to 14 stranded wire Screw Terminal Torque: 0.5 Nm Common Specifications
Supply Supply Voltage, Universal: 21.6 to 253 VAC, 50 to 60 Hz or 19.2 to 300 VDC Max. Required Power: = 2.5 W Internal Power Dissipation: = 2.0 W Isolation Voltage Test Voltage: 2.3 kVAC Working Voltage: 250 VAC (reinforced)/500n VAC (basic) Response Time: Response Time: (0 to 90%, 100 to 10%) < 20 ms Auxiliary Supplies 2-wire Loop Supply: > 16 V @ 20 mA 3-wire Loop Supply: > 18 to < 28 V @ 23 to 0 mA Loop Supply Limitation: 27 to 35 mA avg., < 80 mA peak Reference Voltage: 2.5 VDC ±0.5% Reference Voltage, Load: 0 to 15 mA Current Limit, Reference Voltage: < 60 mA Programming: Communication enabler 4511/Programming front 4501 Signal Dynamics, Input: 24 bit Signal Dynamics, Output: 18 bit Signal/Noise Ratio: > 60 dB Bandwidth: > 40 Hz Accuracy: Better than 0.05% of selected range EMC Immunity Iinfluence: < ±0.5% of span Extended EMC Immunity: NAMUR NE21, A Criterion, Burst: < ±1% of span
Conducted Emission, class A: 150 kHz to 10 MHz Input Specifications Current Input
Signal Range: ±100 mA Programmable Measurement Ranges: 0 to 1, 0 to 5, 1 to 5, 0 to 20, 4 to 20,
±1, ±5, ±10, ±20, ±50, ±100 mA
Custom Configurable Signal Range: ±100 mA Min. Measurement Range (span): 0.5 mA Input Voltage Drop: 0.6 V @ 20 mA nom. Voltage Input
Signal range: ±300 VDC Programmable Measurement Ranges: 0 to 0.1, 0 to 1, 0.2 to 1, 0 to 2.5, 0 to 5,
1 to 5, 0 to 10, 2 to 10, 0 to 100, 0 to 300, ±0.1, ±1, ±2.5, ±5, ±10, ±100, ±300 V Custom Configurable Signal Range:±300 V Min. Measurement Range (span): 25 mV Input Resistance: Nom. 3 MΩ (> 2.5 VDC) Input Resistance:Nom. > 10 MΩ (= 2.5 VDC) Potentiometer Input 3-wire Potentiometer Input: 0 to 100% Reference Voltage: 2.5 V Calibration Resistance: 5 kΩ Min. Potentiometer Resistance: 200 Ω Output Specifications
Current Output Signal Range: 0 to 23 mA (unipolar) Signal Range: -23 to 23 mA (bipolar) Custom Config. Output Range: ±20 mA Min. Signal Range: 4 mA Load (@ Current Output): = 1000 Ω/± 20 V @ ±20 mA Current Limit: = 28 mA (unipolar) Current Limit: ± 28 mA (bipolar) Load Stability: = 0.001% of span / 100 Ω Response Time, Programmable: 0.0 to 60.0 s Passive 2-wire mA Output
Programmable Ranges: 0 to 20 and 4 to 20 mA Ext. 2-Wire Loop Supply Range: 3.5 to 28.8 VDC
Voltage Output
Programmable Signal Ranges: 0/0.2 to 1; 0/1 to 5 ; 0/2 to 10 V Programmable Signal Ranges: ±1, ±5 and ±10 V Programmable Signal Ranges:Direct or Inverted action Load (@ Voltage Output): = 500 kΩ Response Time, Programmable: 0.0 to 60.0 s Shunted Voltage Output Signal Range: ± 1.2 V/± 12 V Programmable Standard Ranges: 0 to 1, 0 to 2.5, 0 to 5, 1 to 5, 0 to 10, 2 to 10 V ±1, ±2.5, ±5, ±10 V Min. Span: 0.8 V Custom Config. Output Range: ±10 V Load, Min: > 500 kΩ
Buffered Voltage Output
Signal range: ± 23 V Programmable Standard Ranges: 0 to 1, 0.2 to 1, 0 to 2.5, 0 to 5,1 to 5, 0 to 10, 2 to 10, 0 to 20, 4 to 20; ±1, ±2.5, ±5, ±10, ±20 V Min. Span: 0.8 V Custom Config. Output Range: ±20 V Current Limit: < 50 mA Load, Min: > 2 kΩ Observed Authority Requirements
LVD: 2014/35/EU EMC: 2014/30/EU RoHS: 2011/65/EU Approvals
UL: UL 508/CC22.2 no. 14
† All amounts shown in EUR, GBP, or USD
We noticed you are from the US. Visit your local site for regional offers and live support.