Cookies on the OMEGA websites We use cookies on this website, these cookies are essential for the website to work correctly.If you continue without changing your settings, we'll assume that you are happy to receive all cookies on this website.To find out more information about these cookies please click here.
Advanced Features
• The DRST-FR signal converter can be configured with OMSET software in a standard PC
and the TXUN-KIT communications unit. Application
• The f/I function performs frequency to current and voltage conversion.
• The f/f function can be used for pulse division or multiplication and as a buffer collecting fast pulse trains.
• A scale factor may be entered in all functions. Using both digital inputs, pulse addition or subtraction are possible.
• The frequency generator function is used as e.g. a time base or clock generator.
• Input and supply polarity reversal protection. Current and voltage output signals galvanically separated from the supply and the inputs.
• Programmable digital outputs including NPN, PNP or relay options. Technical Characteristics
• 5 front LEDs, indicating f1 and f2 active inputs (not NPN), Dig.out.1 and 2 active outputs, and a programmable error signal.
• Analog current output can be configured to any current within 0 to 20 mA range.
• Voltage output range is selectable between 0 to 10 Vdc and 0 to 1 Vdc by use of internal jumpers.
• Input range: Frequency: 0 to 20,000 Hz Sensor types: NAMUR, tacho, NPN, PNP, TTL, S0
• Output range: Current and voltage output: 0 to 20 mA / 0...10 V Relay outputs: 0 to 20 Hz NPN and PNP output as f/f: 0 to 1000 Hz NPN and PNP output as generator: 0 to 20,000 Hz
Specifications Environmental Conditions Operating Temperature: -20 to 60°C Calibration Temperature: 20 to 28°C Relative Humidity: < 95% RH (non-cond.) Protection Degree: IP20 Mechanical Specifications Dimensions (HxWxD): 109 x 23.5 x 130 mm Weight Approx: 240 g DIN Rail Type: DIN 46277 Wire Size: 1 x 2.5 mm2 stranded wire Screw Terminal Torque: 0.5 Nm Common Specifications Supply Supply Voltage, Universal:21.6 to 253 Vac, 50 to 60 Hz or 19.2 to 300 Vdc Fuse: 400 mA SB / 250 Vac Max. Required Power: 3.5 W Internal Power Dissipation:3 W Isolation Voltage Isolation Voltage, Test/Working: 3.75 kVac / 250 Vac Power-Up Delay: 0 to 999 s Warm-Up Time:1 min. Programming: Loop Link Signal/Noise Ratio: Min. 60 dB Response Time, Analog:< 60 ms + period Response Time, Digital Output: < 50 ms + period Signal Dynamics, Output:16 bit Effect of Supply Voltage Change: < 0.005% of span/Vdc Auxiliary Voltage: NAMUR Supply: 8.3 Vdc ±0.5 Vdc / 8 mA S0 Supply: 17 Vdc/20 mA NPN/PNP Supply: 17 Vdc/20 mA Special Supply (Programmable): 5 to 17 Vdc/20 mA Temperature Coefficient:< ±0.01% of span/°C Linearity Error: < 0.1% of span EMC Immunity Influence: < ±0.5% Input Specifications Common Input Specifications Max. Offset: 90% of selected max. frequency Measurement Range: 0 to 20 kHz Min. Measurement Range: 0.001 Hz Max. Frequency, with Input Filter ON: 50 Hz Min. Period Time with Input Filter ON: 20 ms Input Types: NAMUR acc. to DIN 19234 Input Types:Tacho Input Types:NPN/PNP Input Types:2-phase encoder Input Types:TTL Input Types:S0 acc. to DIN 43864 Output Specifications Common Output Specifications Updating Time: 20 ms Current Output Signal Range: 0 to 20 mA Min. Signal Range: 5 mA Load (@ Current Output): ≤ 600 Ω Load Stability: ≤ 0.01% of span/100 Ω Current Limit: < 23 mA Voltage Output Signal Range: 0 to 10 Vdc Min. Signal Range: 250 mV Load (@ Voltage Output): ≥ 500 kΩ Relay Output Max. Switching Frequency: 20 Hz Max. Voltage: 250 VRMS Max. Current: 2 AAC Max. AC Power: 100 VA Max. Load at 24 Vdc:1 A Other Output Types: Active outputs (NPN/PNP) Other Output Types: f/f Converter Output Other Output Types: Frequency generator Of Span: = of the presently selected range Observed Authority Requirements EMC: 2014/30/EU LVD: 2014/35/EU EAC: TR-CU 020/2011