CLAMP-ON ULTRASONIC ENERGY FLOWMETER - Discontinued

FDT-40E Series

CLAMP-ON ULTRASONIC ENERGY FLOWMETER | FDT-40E Series

CLAMP-ON ULTRASONIC ENERGY FLOWMETER

CE
  • Bi-Directional Flow/Energy Measurement
  • Rugged, Aluminum Enclosure
  • Rate and Total Backlit Display
  • 4 to 20 mA and Dual Alarm Outputs
  • USB Programming Port
  • RS485 MODBUS® Network Connection

Description

Discontinued, no replacement.

.
Find how a Ultrasonic flow meter works on this link.

FDT-40E Series ultrasonic flow and energy meters clamp on to the outside of pipes and do not come in contact with the internal liquid. The technology has inherent advantages over alternate devices including: low-cost installation, no pressure head loss, no moving parts to maintain or replace, no fluid compatibility issue, and a large, bi-directional measuring range that ensures reliable readings even at very low and high flow rates. FDT-40E Series is available in a variety of configurations that permit the user to select a meter with features suitable to meet particular application requirements.

Specifications
System
Liquid Types: Most clean liquids or liquids containing small amounts of suspended solids or gas bubbles
Velocity Range: Bi-directional to greater than 40 FPS (12 MPS)
Flow Accuracy:
    Larger Than 50 mm (2"): ±1% of reading or ±0.01 FPS (0.003 MPS), whichever is greater
    25 to 50 mm (1 to 2"): ±1% of reading or ±0.04 FPS (0.012 MPS), whichever is greater
    19 mm (¾") and Smaller: ±1% of full scale
Temperature Accuracy:
    Absolute: 0.25°C (0.45°F)
    Difference: 0.1°C (0.18°F)
Energy Temperature Range: 0 to 100°C (32 to 212°F)
Sensitivity Flow: 0.001 FPS (0.0003 MPS)
Temperature: 0.025°C (0.05°F)
Repeatability: 0.5% of reading Transmitter
Power Requirements (AC): 95 to 264 Vac 47 to 63 Hz @ 17 VA maximum standard, 20 to 28 Vac 47 to 63 Hz @ 0.35 A maximum (“-24VAC” models), 10 to 28 Vdc @ 5 W maximum (“-VDC” models)
Protection: Auto resettable fuse, reverse polarity and transient suppression
Display: Two line LCD, LED backlit; top row 18 mm (0.7") height, 7-segment; bottom row 9 mm (0.35") height, 14-segment
Icons: RUN, PROGRAM, RELAY1, RELAY2
Flow Rate Indication: 8-digit positive, 7-digit negative maximum; auto decimal, lead zero blanking
Flow Totalizer: 8-digit positive, 7-digit negative maximum (re-set via keypad press, software, network command or momentary contact closure
Enclosure NEMA 4 (IP65) Construction: Powder-coated aluminum, polycarbonate, stainless steel, polyurethane, nickel-plated steel mounting brackets
Size (Electronic Enclosure Only): 152 W x 112 H x 56 mm D (6.0 x 4.4 x 2.2")
Conduit Holes: (2) ½ NPT female (1) ¾ NPT female
Temperature: -40 to 85°C (-40 to 185°F)
RTD: Platinum 385, 1000O, 3-wire
Configuration: Via optional keypad or PC running software (Note: not all configuration parameters are available from the keypad – i.e. flow and temperature calibration and advanced filter settings)
Engineering Units Flow Meter: Feet, gallons, cubic feet, million gallons, barrels (liquid and oil), acre-feet, lbs, meters, cubic meters, liters, million liters, kg
Engineering Units Energy Meter: BTU, MBTU, MMBTU, Tons
Inputs/Outputs USB 2.0: For connection of a PC running configuration utility
    RS485: MODBUS RTU command set
    4 to 20 mA: 12-bit, internal power, can span negative to positive flow/energy rates
Transducers
Construction
    Standard (FDT-41 thru 46): NEMA 6 (IP67), PVC, PEI, Nylon cord grip, PVC cable jacket
    Temperature: -40 to 85°C (-40 to 185°F)
    FDT-41 thru 46 with “-HT” option, FDT-47 and FDT-48: NEMA 6 (IP67), CPVC, PEI, Nylon cord grip, PVC cable jacket
    Temperature: -40 to 121°C (-40 to 250°F)
    FDT-47 “-HT”: NEMA 6 (IP67), PTFE, polyimide, Nickel-plated brass cord grip, PFA cable jacket
    Temperature: -40 to 176°C (-40 to 350°F)
Frequency:
    FDT-41 thru 46: 2 MHz
    FDT-47: 1 MHz
    FDT-48: 500 KHz
Cables: RG59 coaxial, 75 Ω or twin axial, 78 Ω (optional armored conduit)
Cable Length: Standard 6 m (20') [300 m (990') maximum in 3 m (10') increments; submersible conduit limited to 30 m (100') for transducers]
Software Utilities Utilized to configure, calibrate and troubleshoot flowmeters. Connection via USB A/B cable; software is compatible with Windows 2000, Windows XP, Windows Vista® and Windows® 7
RS485 Network All FDT-40 meters come equipped with RS485 drivers and utilize a MODBUS RTU command set (data can be returned in single-precision, doubleprecision, integer or floating point values). Up to 126 units products can be run on a single daisy-chain network and be individually queried for flow rate, positive flow accumulator, negative flow accumulator and signal strength. Flow accumulators can be cleared at discrete addresses or globally. The RS485 network is also compatible with direct to Excel, application.
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
FDT-40E
Consult Sales  
Availability: 
 
 
Energy flowmeter display 95 to 264 Vac, temperature range 0 to 100°C (32 to 212°F)
FDT-40E-VDC
Consult Sales  
Availability: 
 
 
Energy flowmeter display 10 to 28 Vdc, temperature range 0 to 100°C (32 to 212°F)
FDT-40E-24VAC
£3,440.00
Availability: 5 weeks
 
Energy flowmeter display 24 Vac, temperature range 0 to 100°C (32 to 212°F)
FDT-40E-HT
Consult Sales  
Availability: 
 
 
Energy flowmeter display 95 to 264 Vac, temperature range -40 to 177°C (-40 to 350°F)
FDT-40E-VDC-HT
£3,309.83
Availability: 5 weeks
 
Energy flowmeter display 10 to 28 Vdc, temperature range -40 to 177°C (-40 to 350°F)
FDT-40E-24VAC-HT
£3,440.00
Availability: 5 weeks
 
Energy flowmeter display 24 Vac, temperature range -40 to 177°C (-40 to 350°F)
Accessory Remote Transducers (Display Sold Separately)
Remote Transducers for ANSI Pipe
FDT-41-ANSI
Consult Sales  
Availability: 
 
 
Transducer for 1/2" ANSI pipe
FDT-42-ANSI
£555.90
Availability: 2 weeks
 
Transducer for 3/4" ANSI pipe
FDT-43-ANSI
Consult Sales  
Availability: 
 
 
Transducer for 1" ANSI pipe
FDT-44-ANSI
Consult Sales  
Availability: 
 
 
Transducer for 1 1/4" ANSI pipe
FDT-45-ANSI
£605.93
Availability: In Stock
 
Transducer for 1 1/2" ANSI pipe
FDT-46-ANSI
Consult Sales  
Availability: 
 
 
Transducer for 2" ANSI pipe
FDT-41-ANSI-100FT
Consult Sales  
Availability: 
 
 
Transducer for 1/2" ANSI pipe with 100 ft of cable
FDT-42-ANSI-100FT
Consult Sales  
Availability: 
 
 
Transducer for 3/4" ANSI pipe with 100 ft of cable
FDT-43-ANSI-100FT
Consult Sales  
Availability: 
 
 
Transducer for 1" ANSI pipe with 100 ft of cable
FDT-44-ANSI-100FT
Consult Sales  
Availability: 
 
 
Transducer for 1 1/4" ANSI pipe with 100 ft of cable
FDT-45-ANSI-100FT
Consult Sales  
Availability: 
 
 
Transducer for 1 1/2" ANSI pipe with 100 ft of cable
FDT-46-ANSI-100FT
Consult Sales  
Availability: 
 
 
Transducer for 2" ANSI pipe with 100 ft of cable
FDT-41-ANSI-HT
£999.66
Availability: 8 weeks
 
High temperature transducer for 1/2" ANSI pipe
FDT-42-ANSI-HT
£999.67
Availability: 8 weeks
 
High temperature transducer for 3/4" ANSI pipe
FDT-43-ANSI-HT
£1,056.20
Availability: 8 weeks
 
High temperature transducer for 1" ANSI pipe
FDT-44-ANSI-HT
£1,056.00
Availability: 8 weeks
 
High temperature transducer for 1 1/4" ANSI pipe
FDT-45-ANSI-HT
£1,056.20
Availability: 8 weeks
 
High temperature transducer for 1 1/2" ANSI pipe
FDT-46-ANSI-HT
£1,121.00
Availability: 8 weeks
 
High temperature transducer for 2" ANSI pipe
FDT-41-ANSI-HT-100FT
£1,236.00
Availability: 8 weeks
 
High temperature transducer for 1/2" ANSI pipe with 100 ft of cable
FDT-42-ANSI-HT-100FT
£1,236.00
Availability: 8 weeks
 
High temperature transducer for 3/4" ANSI pipe with 100 ft of cable
FDT-43-ANSI-HT-100FT
£1,282.00
Availability: 8 weeks
 
High temperature transducer for 1" ANSI pipe with 100 ft of cable
FDT-44-ANSI-HT-100FT
£1,282.00
Availability: 8 weeks
 
High temperature transducer for 1 1/4" ANSI pipe with 100 ft of cable
FDT-45-ANSI-HT-100FT
£1,282.00
Availability: 8 weeks
 
High temperature transducer for 1 1/2" ANSI pipe with 100 ft of cable
FDT-46-ANSI-HT-100FT
£1,327.00
Availability: 8 weeks
 
High temperature transducer for 2" ANSI pipe with 100 ft of cable
Remote Transducers for Copper Pipe
FDT-41-CP
Consult Sales  
Availability: 
 
 
Transducer for 1/2" Copper pipe
FDT-42-CP
£555.90
Availability: 2 weeks
 
Transducer for 3/4" Copper pipe
FDT-43-CP
Consult Sales  
Availability: 
 
 
Transducer for 1" Copper pipe
FDT-44-CP
Consult Sales  
Availability: 
 
 
Transducer for 1 1/4" Copper pipe
FDT-45-CP
Consult Sales  
Availability: 
 
 
Transducer for 1 1/2" Copper pipe
FDT-46-CP
Consult Sales  
Availability: 
 
 
Transducer for 2" Copper pipe
FDT-41-CP-100FT
Consult Sales  
Availability: 
 
 
Transducer for 1/2" Copper pipe with 100 ft of cable
FDT-42-CP-100FT
Consult Sales  
Availability: 
 
 
Transducer for 3/4" Copper pipe with 100 ft of cable
FDT-43-CP-100FT
Consult Sales  
Availability: 
 
 
Transducer for 1" Copper pipe with 100 ft of cable
FDT-44-CP-100FT
Consult Sales  
Availability: 
 
 
Transducer for 1 1/4" Copper pipe with 100 ft of cable
FDT-45-CP-100FT
Consult Sales  
Availability: 
 
 
Transducer for 1 1/2" Copper pipe with 100 ft of cable
FDT-46-CP-100FT
Consult Sales  
Availability: 
 
 
Transducer for 2" Copper pipe with 100 ft of cable
FDT-41-CP-HT
£999.67
Availability: 8 weeks
 
High temperature transducer for 1/2" Copper pipe
FDT-42-CP-HT
£999.67
Availability: 8 weeks
 
High temperature transducer for 3/4" Copper pipe
FDT-43-CP-HT
£1,056.00
Availability: 8 weeks
 
High temperature transducer for 1" Copper pipe
FDT-44-CP-HT
£1,056.00
Availability: 8 weeks
 
High temperature transducer for 1 1/4" Copper pipe
FDT-45-CP-HT
£1,056.00
Availability: 8 weeks
 
High temperature transducer for 1 1/2" Copper pipe
FDT-46-CP-HT
£1,121.00
Availability: 8 weeks
 
High temperature transducer for 2" Copper pipe
FDT-41-CP-HT-100FT
£1,236.00
Availability: 8 weeks
 
High temperature transducer for 1/2" Copper pipe with 100 ft of cable
FDT-42-CP-HT-100FT
£1,236.00
Availability: 8 weeks
 
High temperature transducer for 3/4" Copper pipe with 100 ft of cable
FDT-43-CP-HT-100FT
£1,282.00
Availability: 8 weeks
 
High temperature transducer for 1" Copper pipe with 100 ft of cable
FDT-44-CP-HT-100FT
£1,282.00
Availability: 8 weeks
 
High temperature transducer for 1 1/4" Copper pipe with 100 ft of cable
FDT-46-CP-HT-100FT
£1,327.00
Availability: 8 weeks
 
High temperature transducer for 2" Copper pipe with 100 ft of cable
FDT-45-CP-HT-100FT
£1,282.00
Availability: 8 weeks
 
High temperature transducer for 1 1/2" Copper pipe with 100 ft of cable
Remote Transducers for Tubing
FDT-41-TUBE
Consult Sales  
Availability: 
 
 
Transducer for 1/2" tubing
FDT-42-TUBE
Consult Sales  
Availability: 
 
 
Transducer for 3/4" tubing
FDT-43-TUBE
Consult Sales  
Availability: 
 
 
Transducer for 1" tubing
FDT-44-TUBE
Consult Sales  
Availability: 
 
 
Transducer for 1 1/4" tubing
FDT-45-TUBE
Consult Sales  
Availability: 
 
 
Transducer for 1 1/2" tubing
FDT-46-TUBE
Consult Sales  
Availability: 
 
 
Transducer for 2" tubing
FDT-41-TUBE-100FT
Consult Sales  
Availability: 
 
 
Transducer for 1/2" tubing with 100 ft of cable
FDT-42-TUBE-100FT
Consult Sales  
Availability: 
 
 
Transducer for 3/4" tubing with 100 ft of cable
FDT-43-TUBE-100FT
Consult Sales  
Availability: 
 
 
Transducer for 1" tubing with 100 ft of cable
FDT-44-TUBE-100FT
Consult Sales  
Availability: 
 
 
Transducer for 1 1/4" tubing with 100 ft of cable
FDT-45-TUBE-100FT
£938.21
Availability: 8 weeks
 
Transducer for 1 3/4" tubing with 100 ft of cable
FDT-45-TUBE-100FT
£938.21
Availability: 8 weeks
 
Transducer for 1 1/2" tubing with 100 ft of cable
FDT-46-TUBE-100FT
Consult Sales  
Availability: 
 
 
Transducer for 2" tubing with 100 ft of cable
FDT-41-TUBE-HT
£999.67
Availability: 8 weeks
 
High temperature transducer for 1/2" tubing
FDT-42-TUBE-HT
£999.67
Availability: 8 weeks
 
High temperature transducer for 3/4" tubing
FDT-43-TUBE-HT
£1,056.00
Availability: 6 weeks
 
High temperature transducer for 1" tubing
FDT-44-TUBE-HT
£1,056.00
Availability: 8 weeks
 
High teperature transducer for 1 1/4" tubing
FDT-45-TUBE-HT
£1,056.00
Availability: 8 weeks
 
High teperature transducer for 1 1/2" tubing
FDT-46-TUBE-HT
£1,121.00
Availability: 6 weeks
 
High temperature transducer for 2" tubing
FDT-41-TUBE-HT-100FT
£1,236.00
Availability: 8 weeks
 
High temperature transducer for 1/2" tubing with 100 ft of cable
FDT-42-TUBE-HT-100FT
£1,236.00
Availability: 8 weeks
 
High temperature transducer for 3/4" tubing with 100 ft of cable
FDT-43-TUBE-HT-100FT
£1,282.00
Availability: 8 weeks
 
High temperature transducer for 1" tubing with 100 ft of cable
FDT-44-TUBE-HT-100FT
£1,282.00
Availability: 8 weeks
 
High temperature transducer for 1 1/4" tubing with 100 ft of cable
FDT-45-TUBE-HT-100FT
£1,282.00
Availability: 8 weeks
 
High temperature transducer for 1 1/2" tubing with 100 ft of cable
FDT-46-TUBE-HT-100FT
£1,327.00
Availability: 8 weeks
 
High temperature transducer for 2" tubing with 100 ft of cable
RemoteTransducers
FDT-47
£836.61
Availability: 2 weeks
 
Transducer for 2 to 24" pipe
FDT-47-100FT
£1,070.13
Availability: 6 weeks
 
Transducer for 2 to 24" pipe with 100 ft of cable
FDT-47-HT
£3,278.00
Availability: 8 weeks
 
High temperature transducer for 2 to 24" pipe
FDT-47-HT-100FT
£3,510.00
Availability: 8 weeks
 
High temperature transducer for 2 to 24" pipe with 100 ft of cable
FDT-48
£1,343.00
Availability: 8 weeks
 
Transducer for pipes over 24"
FDT-48-100FT
£1,579.00
Availability: 8 weeks
 
Transducer for pipe over 24" with 100 ft of cable
Accessories
FDT-40-PC-CABLE
£61.01
Availability: 6 weeks
 
Optional USB PC programming cable
FDT-40-CABLE GLAND
£31.98
Availability: 2 weeks
 
Optional cable gland
FDT-40-BHC
£84.64
Availability: 5 weeks
 
Brad Harrison connector for the FDT-40 Series
FDT-40-RTDCONN
£88.72
Availability: 6 weeks
 
RTD Pig Tail (connection adapter)
FDT-40-RTD1
£554.43
Availability: 6 weeks
 
RTD kit, clamp-on, 130C, 1000Ω 6.1 m (20')
FDT-40-RTD2
£695.53
Availability: 2 weeks
 
RTD kit, clamp-on, 200C, 1000Ω 6.1 m (20')
FDT-40-RTD3
£1,020.00
Availability: 6 weeks
 
RTD kit, insertion, 3 x 1/4", 126C, 1000Ω Platinum RTD
FDT-GREASE
£62.38
Availability: 2 weeks
 
Replacement acoustic couplant 150 g (5.3 oz)
FDT-HT-GREASE
£140.18
Availability: 2 weeks
 
High temperature acoustic couplant 56 g (2 oz)
FDT-NS-GREASE
£62.38
Availability: 6 weeks
 
Non-silicone acoustic couplant 79 g (2.8 oz)
All amounts shown in EUR, GBP, or USD
Note: Comes complete with operator’s manual. Transducers come with mounting gel.

Transducers sold separately.


Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Pipe and Tubing Sizes select from:
41 for 1/2 Inch
42 for 3/4 Inch
43 for 1 Inch
44 for 1 1/4 Inch
45 for 1 1/2 Inch
46 for 2 Inch
47 for 2 to 24 Inch
48 for Pipes over 24 inch

(2) Pipe and Tubing Material select from:
ANSI for ANSI pipe
CP for Copper pipe
TUBE for Plastic tubing

(3) High Temperature select from:
Nothing(leave field blank) for None
-HT for High temp transducers

(4) Cable Length select from:
Nothing(leave field blank) for Standard 6 m (20 feet)
-100FT for 30 m (100 feet)
Note: All combinations may not be valid, check spec sheet for valid part numbers.