Low Noise Thermocouple Probes With Standard Size Plug

G(*)QIN and G(*)QSS

Low Noise Thermocouple Probes With Standard Size Plug | G(*)QIN and G(*)QSS

Low Noise Thermocouple Probes With Standard Size Plug

  • Made from Class 1 Tolerance MI Cable
  • Connector Body Rated to 220°C
  • Probes Individually Pressure and Insulation Tested
  • Earth-Strap Connection Provides Protection Against Electrical Noise
  • Earth-Strap Clamps Plug & Socket Together for Additional Mechanical Rigidity
  • Supplied Mating Socket has Write-On Area for Easy Identification
  • Mating Connector, Cable Clamp, Write-On Windows and Ground Strap Sold Separately
Thermocouples - View related products

Description


The OMEGA™ low noise thermocouple probes and connectors maintain an electrical connection from the sheath of the probe, through the connectors, all the way to your instrumentation. This system assures high accuracy measurements, providing protection against electrical noise. The external strap maintains the electrical connection of the sheilding wire, and also strengthens the mechanical connection between the two connectors. The socket features a handy write-on area, for easy identification.

Low Noise Thermocouple Probe Diagram

Quick Disconnect Probes with Standard Size Low Noise Connectors
Alloy/IEC
Colour Code
Sheath
Dia. mm
Model No.
300 mm Length
Model No.
450 mm Length
Model No.
600 mm Length
K
CHROMEGA-® ALOMEGA™
SS Sheath
1.5
3.0
4.5
6.0
GKQSS-IM15(*)-300
GKQSS- IM30(*)-300
GKQSS-IM45(*)-300
GKQSS-IM60(*)-300
GKQSS-IM15(*)-450
GKQSS- IM30(*)-450
GKQSS-IM45(*)-450
GKQSS-IM60(*)-450
GKQSS-IM15(*)-600
GKQSS- IM30(*)-600
GKQSS-IM45(*)-600
GKQSS-IM60(*)-600
K
CHROMEGA-® ALOMEGA™
Inconel Sheath
1.5
3.0
4.5
6.0
GKQIN-IM15(*)-300
GKQIN- IM30(*)-300
GKQIN-IM45(*)-300
GKQIN-IM60(*)-300
GKQIN-IM15(*)-450
GKQIN- IM30(*)-450
GKQIN-IM45(*)-450
GKQIN-IM60(*)-450
GKQIN-IM15(*)-600
GKQIN- IM30(*)-600
GKQIN-IM45(*)-600
GKQIN-IM60(*)-600
K
CHROMEGA-® ALOMEGA™
Super OMEGACLAD™ XL Sheath
1.5
3.0
4.5
6.0
GKQXL-IM15(*) -300
GKQXL-IM30(*)-300
GKQXL-IM45(*)-300
GKQXL-IM60(*)-300
GKQXL-IM15(*) -450
GKQXL-IM30(*)-450
GKQXL-IM45(*)-450
GKQXL-IM60(*)-450
GKQXL-IM15(*) -600
GKQXL-IM30(*)-600
GKQXL-IM45(*)-600
GKQXL-IM60(*)-600
T
COPPER-CONSTANTAN
SS Sheath
1.5
3.0
4.5
6.0
GTQSS-IM15(*)-300
GTQSS- IM30(*)-300
GTQSS-IM45(*)-300
GTQSS-IM60(*)-300
GTQSS-IM15(*)-450
GTQSS- IM30(*)-450
GTQSS-IM45(*)-450
GTQSS-IM60(*)-450
GTQSS-IM15(*)-600
GTQSS- IM30(*)-600
GTQSS-IM45(*)-600
GTQSS-IM60(*)-600
J
IRON- CONSTANTAN
SS Sheath
1.5
3.0
4.5
6.0
GJQSS-IM15(*)-300
GJQSS- IM30(*)-300
GJQSS-IM45(*)-300
GJQSS-IM60(*)-300
GJQSS-IM15(*)-450
GJQSS- IM30(*)-450
GJQSS-IM45(*)-450
GJQSS-IM60(*)-450
GJQSS-IM15(*)-600
GJQSS- IM30(*)-600
GJQSS-IM45(*)-600
GJQSS-IM60(*)-600
N
OMEGA-P™-OMEGA-N™
Super OMEGACLAD™ XL Sheath
1.5
3.0
4.5
6.0
GNQXL-IM15(*) -300
GNQXL-IM30(*)-300
GNQXL-IM45(*)-300
GNQXL-IM60(*)-300
GNQXL-IM15(*) -450
GNQXL-IM30(*)-450
GNQXL-IM45(*)-450
GNQXL-IM60(*)-450
GNQXL-IM15(*) -600
GNQXL-IM30(*)-600
GNQXL-IM45(*)-600
GNQXL-IM60(*)-600
Super OMEGACLAD™XL sheathed probes highlighted in yellow.
* Specify junction type: G (Grounded), E (Exposed), or U (Insulated).
To specify Inconel® probes, replace "SS" in Model Number with "IN". Example: GKQIN-IM30U-300, Quick Disconnect Type K Probe with Low Noise, Standard connectors, Inconel sheath, 3.0 mm dia, 300 mm length.

Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
GKQIN-IM60U-300
Consult Sales  
Availability: 
 
 
Quick disconnect probe, type K, SS sheath, 6 mm O.D., insulated junction, 300 mm length
GTQSS-IM60U-600
Consult Sales  
Availability: 
 
 
Quick disconnect probe, type T, SS sheath, 6 mm O.D., insulated junction, 600 mm length
GJQSS-IM15U-300
Consult Sales  
Availability: 
 
 
Quick disconnect probe, type J, SS sheath, 1.5 mm O.D., Insulated junction, 300 mm length
Accessories
GS-GST-10
£6.52
Availability: 2 weeks
 
Extra replacement Earth-Straps (Pack of 10)
WCP-L
£1.77
Availability: 5 weeks
 
Extra replacement write-on windows for connector face (Pack of 5)
WCP-GST
£1.30
Availability: 5 weeks
 
Extra replacement write-on windows for connector side (Pack of 5)
Sold Separately, Mating Connector & clamp & other accessory Part Number
HGST-J-F
£14.30
Availability: 2 weeks
 
Compliant upon request High performance, low noise, high temperature Standard mating connector
HGST-K-F
£14.30
Availability: 2 weeks
 
Compliant upon request High performance, low noise, high temperature Standard mating connector
HGST-E-F
£14.03
Availability: 6 weeks
 
Compliant upon request High performance, low noise, high temperature Standard mating connector
HGST-T-F
£14.30
Availability: 2 weeks
 
Compliant upon request High performance, low noise, high temperature Standard mating connector
PCLM-GST
£1.77
Availability: 2 weeks
 
RoHS compliant CABLE CLAMP
GS-GST-10
£6.52
Availability: 2 weeks
 
RoHS compliant Extra ground straps
WCP-GST
£1.30
Availability: 5 weeks
 
RoHS compliant Extra replacement write-on windows, side (Pack of 5)
WCP-L
£1.77
Availability: 5 weeks
 
RoHS compliant Extra replacement write-on windows, connector face (Pack of 5)
All amounts shown in EUR, GBP, or USD
Note: Each probe includes a protective earth strap. For applications not requiring the external earth strap, plastic write-on windows are included with each probe and connector to provide additional write-on areas. Note: Windows cannot be used concurrently with earth strap.
Ordering Example:  (1) WCP-L Extra replacement write-on windows, connector face (Pack of 5), £1.77

Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Thermocouple Type select from:
K for K Type
T for T Type
J for J Type
N for N type
E for E type

(2) Sheath Material select from:
SS for Stainless Steel
IN for Inconel
XL for Super OMEGACLAD™XL (Type K and N only)

(3) Sheath Diameter select from:
15 for 1.5 mm
30 for 3.0 mm
45 for 4.5 mm
60 for 6.0 mm

(4) Thermocouple Junction select from:
U for Insulated
G for Grounded
E for Exposed

(5) Sheath Length select from:
300 for 300 mm
450 for 450 mm
600 for 600 mm
Note: All combinations may not be valid, check spec sheet for valid part numbers.
We noticed you are from the US. Visit your local site for regional offers and live support.