Layer N Banner

Wheatstone Bridge In-Line Signal Conditioner

IN-UVI

in-line bridge input transmitter | IN-UVI

in-line bridge input transmitter

£1,507.42 IN-UVI

CE
  • Wide Range of Switch Selectable Inputs and Outputs
  • Input/Output Isolation
  • 5 V or 10 V excitation built-in
  • 8 switch selectable input ranges from 0.5 to 4 mV/V @ 10 V Excitation
  • Outputs: 4-20 mA, 12 mA Zero ±8 mA, ±5 V, ±10 V, 0-5 V, 0-10 V
  • Rugged Stainless Steel Enclosure, IP65 Protected
  • Output can Be Sent Over Much Longer Distances than Millivolt Signals
Accessories - View related products

Description

The OMEGA IN-UVI in-line signal conditioner is housed in a rugged stainless steel enclosure. The bridge input transmitter supplies a highly regulated excitation voltage of 5 or 10 V for the transducer and converts the millivolt signal of the transducer to 0 to 5, 0 to 10, ±5, ±10 Vdc or 4 to 20, 12 ± 8 mA.

The IN-UVI features include a wide zero adjustment range and an isolated shunt calibration relay for quick field setup. All output options and excitation voltages are switch selectable.

Specifications
Supply Voltage: 22 to 32 V dc, isolated from output
Input Current: 90 mA maximum (must be capable of supplying 200 mA)
Voltage Output: ±5 volts, ±10 volts at 2 mA maximum
Output Resistance: 60 Ω
Noise: 10 mV peak to peak @ 3 mV/V voltage mode (10 Vdc) 20 uA peak to peak current mode
Isolation Input to Output: 500 Vdc
    Capacitance: 0.022 µF
    Resistance: 100 MΩ
Short Circuit Protection: Yes +output to -output
Current Output: 4 to 20 mA, 12 mA zero ±8 mA outputs, switch selectable
Maximum Load Resistance: 700 Ω at 20 mA
Response Time: 200 µS (0 to 63%)*
Excitation Voltage: 5 or 10 V, switch selectable
Excitation Max. Current: 30 mA @ 10 V dc
Sensor Input Range: 0.5 mV/V to 4 mV/V in 0.5 steps
Shunt Cal: Yes; remotely activated
Environmental Protection: IP65
Long Term Zero Drift: 0.1%/year
Operating Temperature: -20 to 60°C
Temperature Affects:
    Zero: 0.0018%/°C (0.001%/°F) (Auto zero front end)
    Span: 0.0045%/°C (0.0025%/°F)
Linearity: 0.01%
Adjustment Range:
    Zero: ±30%
    Span: ±20% fine ±40% coarse
Adjustment Location: Behind connector end caps
EMC Affect: <0.1% per en 61326-1 (industrial)
Dimensions: 134.8 L x 34.8 H x 31.2 mm D
Transducer Requirements:
Bridge Excitation: 5 Vdc or 10 Vdc
Bridge Sensitivity: 1 to 8 mV/V @ 5 Vdc EXC, 0.5 to 4 mV/V for 10 Vdc EXC
Bridge Resistance: 350 to 5000 Ω*
* Time constant 0 to 63% (200 µS for a 350 Ω bridge/1.2 mS for a 5 kΩ bridge)
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
IN-UVI
£1,507.42
Availability: 2 weeks
 
Wheatstone bridge in-line signal conditioner
Accessories
M12.8-S-F-FM
£32.61
Availability: 2 weeks
 
8-pin M12 straight female connector
Cable Assemblies (all Standard Part Numbers include 24AWG Gauge Conductors, 4.5 metre Length)
CA-4PC24-2A-015-INUVI
£155.63
Availability: 6 weeks
 
Cable assembly, 4 conductor, PVC insulation, wiring code 2A
CA-4PC24-3-015-INUVI
£155.63
Availability: 6 weeks
 
Cable assembly, 4 conductor, PVC insulation, wiring code 3
CA-4TE24-3-015-INUVI
Consult Sales  
Availability: 
 
 
Cable assembly, 4 conductor, FEP insulation, wiring code 3
CA-4PC24-4-015-INUVI
£155.63
Availability: 8 weeks
 
Cable assembly, 4 conductor, PVC insulation, wiring code 4
CA-4PC24-4A-015-INUVI
Consult Sales  
Availability: 
 
 
Cable assembly, 4 conductor, PVC insulation, wiring code 4A
CA-4TE24-5-015-INUVI
Consult Sales  
Availability: 
 
 
Cable assembly, 4 conductor, FEP insulation, wiring code 5
CA-4TE24-6-015-INUVI
£155.63
Availability: 6 weeks
 
Cable assembly, 4 conductor, FEP insulation, wiring code 6
CA-4PC24-8-015-INUVI
Consult Sales  
Availability: 
 
 
Cable assembly, 4 conductor, PVC insulation, wiring code 8
CA-4PC24-0-015-INUVI
£156.50
Availability: 8 weeks
 
Cable assembly, 4 conductor, PVC insulation, wiring code 0
CA-4TE24-0-015-INUVI
Consult Sales  
Availability: 
 
 
Cable assembly, 4 conductor, FEP insulation, wiring code 0
CA-6PC24-OUT-015-INUVI
£156.50
Availability: 8 weeks
 
Cable assembly, 6 conductor, PVC insulation, wiring code OUT
All amounts shown in EUR, GBP, or USD
Note: M12 mating connectors are not supplied. Please order separately.
Ordering Example: (1) M12.5-S-F-FM 5-pin M12 connector, £32.61  plus (1) IN-UVI Bridge input transmitter, £1,507.42  plus (1) M12.8-S-F-FM 8-pin M12 connector, £32.61, £32.61 + 1,507.42 + 32.61 = £1,572.64
We noticed you are from the US. Visit your local site for regional offers and live support.