Cookies on the OMEGA websites
We use cookies on this website, these cookies are essential for the website to work correctly.If you continue without changing your settings, we'll assume that you are happy to receive all cookies on this website.To find out more information about these cookies please click here.
CLOSE
Basket  |  Contact  |  Help  | 
Free Phone 0800 488 488
International+44(0) 161 777 6611
Layer N Banner

Ultrasonic Level Transmitter and Controller

LVCN318 Series

Ultrasonic level transmitter | LVCN318 Series

Ultrasonic level transmitter

CE
  • Level Detection, Switch and Control Functions Up to 5.5 metres
  • Fast and Easy Configuration Via Free Software Download and USB Adaptor
  • Narrow 7.6 cm Beam Width and Short 20 cm Dead Band
  • Four Programmable Relays
  • PVDF Transducer and 6P Polycarbonate Enclosure
  • Automatic Temperature Compensation for Accurate Measurement
Level Switches and Transmitters - View related products

Description

Click on this link if you need more information about Level sensor.

OMEGA’s LVCN318 ultrasonic level transmitter and controller provides continuous level measurement up to 5.5 metres with a 4 to 20 mA signal output, and is configured with our free software via USB. The level sensor has 4 programmable relays with selectable hysteresis and fail-safe logic. The embedded level controller can lower cost by replacing external control hardware. This non-contact liquid level sensor is ideally suited for corrosive, sticky or dirty liquids, and is widely selected for day tank, skid, IBC, sump and process tank level applications.

Specifications
Range: 5.5 m (18')
Accuracy: ±0.2% of range
Resolution: 2 mm (0.079")
Dead Band: 20 cm (8")
Beam Width: 7.62 cm (3")
Configuration: USB PC Windows®
USB 2.0 Memory: Non-volatile. The level sensor is configurable via our free PC software and USB.
Supply Voltage: 24 Vdc (loop)
Consumption: 0.5W
Loop Resistance: 400Ω max
Signal Output: 4 to 20 mA, two-wire
Signal Invert: 4 to 20 mA or 20 to 4 mA
Signal Fail-Safe: 4 mA, 20 mA, 21 mA, 22 mA or hold last
Contact Type: (4) SPST relays
Contact Rating: 60 VA, 1A maximum
Contact Fail-Safe: Power loss; hold last
Echo Loss: Open, close or hold last
Hysteresis: Selectable
Process Temperature: -7 to 60°C (20 to 140°F)
Temp Comp: Automatic
Ambient Temperature: -35 to 60°C (-31 to 140°F)
Pressure: Maximum Working Pressure = 2 bar (30 psi)
Enclosure Rating: Type 6P, encapsulated, corrosion resistant and submersible
Encl Material: Polycarbonate
Trans Material: PVDF
Cable Jacket Material: Polyurethane
Cable Type: 9-conductor, shielded
Cable Length: 1.2 m (48")
Process Mount: 2" NPT or G2 (specifiy)
Mount Gasket: FKM
Classification: General purpose
Compliance: CE, RoHS
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
LVCN318
Consult Sales  
Availability: 
 
 
Level transmitter, 4 to 20 mA, 4 relays, USB connector, 5.5 m range. 2" NPT process connection
LVCN318-G
£787.37
Availability: 10 weeks
 
Level transmitter, 4 to 20 mA, 4 relays, USB connector, 5.5 m range, G2 (2" BSPP) process connection
All amounts shown in EUR, GBP, or USD
Note: Comes complete with mounting gasket, and operator’s manual.
We noticed you are from the US. Visit your local site for regional offers and live support.