Option Descriptions:
(1)
Cable Insulation select from:TT for PFA Insulated and Jacketed
PP for PVC Insulated and Jacketed
(2)
Thermocouple Type select from:K for Type K with ANSI Color Code
J for Type J with ANSI Color Code
KI for Type K with IEC Color Code
JI for Type J with IEC color code
(3)
Conductor Size select from:20S for #20AWG Stranded (PFA Insulated Only)
24S for #24AWG Stranded
(4)
Sensor Side Connector select from:SFSR for Straight Socket Style M12
RFSR for Right Angled Socket Style M12
SMSR for Straight Plug Style M12
RMSR for Right Angled Plug Style M12
(5)
Process End Termination select from:FL for Stripped Leads
SMSR for Straight Plug Style M12
RMSR for Right Angled Plug Style M12
SFSR for Straight Socket Style M12
RFSR for Right Angled Socket Style M12
SMPW-CC for Miniature Thermocouple Connector
OSTW-CC for Full Size Thermocouple Connector
(6)
Cable Length select from:3 for 3 meters Long
5 for 5 meters Long
10 for 10 meters Long
15 for 15 meters Long
20 for 20 meters Long
(7)
Number of TCs select from: for Single
-DUAL for Dual Cable
Note: All combinations may not be valid, check spec sheet for valid part numbers.