4 Channel Process Current Data Logger, ±1, ±25 and ±100mA Ranges - Discontinued

OM-CP-QUADPROCESS

4 channel process current logger | OM-CP-QUADPROCESS

4 channel process current logger

5 year warranty CE
  • 16-Bit Resolution
  • Programmable Engineering Units, Scale Factor, and Offset Value
  • Memory Wraparound
  • Miniature Size
  • User Calibration Through Software
  • Real-Time Operation

Description

This product is no longer available. Please see OM-CP-XPROCESS-SERIES for a newer product with improved features!

More information about how a Data Logger works in this link.

The OM-CP-QUADPROCESS is a low-cost, high-resolution, miniature battery-powered standalone data logger for automatically recording electrical current up to 120 mA. It uses a 16-bit ADC to achieve a resolution of up to 0.05uA. In addition, the OM-CP-QUADPROCESS lets the user store pre-defined units in the device, as well as scale factors and offset values. This allows easy automatic linearisation and scaling of any device that provides a mA analogue output into process units. This portable, easy-to-use device will measure and record up to 32,767 current measurements per channel.

The OM-CP-QUADPROCESS represents a major leap in both size and performance. Its small size allows it to fit almost anywhere. Its real-time clock ensures that all data is time and date stamped. The storage medium is non-volatile solid state memory, providing maximum data security, even if the battery becomes discharged.

Data retrieval is simple. Plug the logger into an available COM port and our easy-to-use software does the rest. The software converts your PC into a real-time strip chart recorder. Data can be printed in graphical or tabular format. It can also be exported to a text or Microsoft Excel file.

SPECIFICATIONS

Nominal Range
±1mA
±25mA
±100mA
Measurement Range
±1.5mA
±30mA
±120mA
Resolution
0.05μA
1μA
5μA
Calibrated Accuracy @25°C
±0.5%FSR
±0.1%FSR
±0.1%FSR
Input Impedence
50Ω
10Ω


Input Channels: 4 non-isolated inputs
Memory: 32,767 readings/channel
Input Connection: Screw terminal
ADC Resolution: 16 bits
Voltage Calibration: Digital calibration available in software
Calibration Date: Automatically recorderd within device to alert user when calibration is required
Recording Interval: 1 second to 12 hours selectable in software
Start Time: Start time and date programmable through software
Memory Wrap Around: Selectable in software
Real-Time Recording: Device may be used with PC to monitor and record data in real time
Time Accuracy: ±1 minute per month at 20°C
Power: 9 V alkaline battery (included)
Battery Life: 1 year typical
Time Accuracy: ±1 minute per month at 20°C
Data Format: Date and time stamped in µA, mA, A and other engineering units programmable through software
Weight: 370 g
Computer Interface: PC serial, RS-232C COM or USB (interface cable required)
Software: XP SP3/Vista/7 and 8 (32-bit and 64-bit)
Operating Environment: -40 to 80°C 0 to 95% RH non-condensing
Dimensions: 26 H x 111 W x 89 mm D
Material: Black anodised aluminium
Place Order(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/ Desc.
Qty
Description
  
OM-CP-QUADPROCESS-1MA
Consult Sales  
Availability: 
 
 
4-channel data logger, ±1 mA range
Click to expand/minimize a list of what others bought with theOM-CP-QUADPROCESS-25MA
OM-CP-QUADPROCESS-25MA
Consult Sales  
Availability: 
 
 
4-channel data logger, ±25 mA range
  
OM-CP-QUADPROCESS-100MA
Consult Sales  
Availability: 
 
 
4-channel data logger, ±100 mA range
Accessories
Click to expand/minimize a list of what others bought with theOM-CP-IFC200
OM-CP-IFC200
£162.18
Availability: In Stock
 
Windows software and 3.5 m USB interface cable
Click to expand/minimize a list of what others bought with theOM-CP-IFC110
OM-CP-IFC110
Consult Sales  
Availability: 
 
 
Windows software and 1.2 m RS-232 cable with DB9F termination
Click to expand/minimize a list of what others bought with theOM-CP-BAT103
OM-CP-BAT103
£40.85
Availability: 2 weeks
 
Replacement 9 V alkaline battery
  
OM-CP-CONNECTOR-3
£10.09
Availability: 2 weeks
 
Replacement 3 position terminal block connector
  
CAL-3-SYSTEM
Consult Sales  
Availability: 
 
 
Traceable calibration certificate with test results
All amounts shown in EUR, GBP, or USD
Note: Operator's manual and PC cable are included with the OM-CP-IFC200 and IFC110 Windows software (software is required to operate the data logger and is sold separately).
Ordering Example:  (1) OM-CP-IFC200 Windows software and USB interface cable, £162.18

Product Manuals:

Download Quick Start - 4/8 Channel DC Current Datalogger
Download OM-CP Series - Data Logger and Software User Guide