Cookies on the OMEGA websites We use cookies on this website, these cookies are essential for the website to work correctly.If you continue without changing your settings, we'll assume that you are happy to receive all cookies on this website.To find out more information about these cookies please click here.
Measures: Voltage (±125 mV, ±1V, ±4V, ±15V, ±60V), Current (±25 mA), Thermocouples (J, K, T, E, R, S, N, B), RTDs (Pt100, Pt1000, 3- and 4-Wire), Resistance (2- and 4-Wire), and Bridge-Based Sensors (Quarter-, Half-, and Full-Bridge)
Simultaneous Sampling at Up to 100 S/s Per Channel
250 Vrms Channel-to-Channel and Channel-to-Ground Isolation
Built-In Thermistor for Cold-Junction Compensation (CJC)
Six-Position Input Screw Terminal Allows Different Measurement Types to be Performed On Each Channel
The new OM-USB-2404-UI provides four channels
of 24-bit universal analog input with integrated signal
conditioning. The device can be used to measure a
variety of sensor types such as RTDs, thermocouples,
load cells, and other powered sensors. The four
channels are individually configurable, so a different
measurement type can be performed on each channel.
All channels are measured simultaneously at up to
100 S/s per channel.
The OM-USB-2404-UI can perform
the following measurements:
• Voltage
• Current
• Thermocouple
• RTD (3- and 4-wire)
• Resistance (2- and 4-wire)
• Bridge-based sensors (quarter-, half-, and full-bridge)
Measurement ranges vary for each type of
measurement (see PDF for complete specifications).
The device features a built-in current and voltage
excitation. The excitation circuit is protected from
overcurrent and overvoltage fault conditions. Each
channel also has a built-in thermistor for cold-junction
compensation (CJC) calculations when measuring
thermocouples. An analog pre-filter removes noise
that may be present in the signals prior to conversion.
With 250 Vac channel-to-channel and channel-to-ground
isolation, the OM-USB-2404-UI protects the
individual channels and connected computer and
ensures a reliable data stream. Each channel has a
detachable six-position screw terminal block for field
wiring connections.
The OM-USB-2404-UI ships with a 2 m (6') USB
cable and is powered by the 5V USB supply from
your computer. No external power is required.
The OM-USB-2404-UI is a USB 2.0 high-speed device
that is supported under popular Microsoft Windows®
operating systems. The OM-USB-2404-UI is fully
compatible with both USB 1.1 and USB 2.0 ports.
Software
The OM-USB-2404-UI module ships with an
impressive array of software, including the new
TracerDAQ®, a full-featured, out-of-the-box data
logging, viewing, and analysis application. Driver
support and detailed example programs are included
for Universal Library programming libraries for
Microsoft® Visual Studio® programming languages, and
other languages, including DASYLab®, and ULx for NI
LabVIEW® (comprehensive library of Vls and example
programs compatible with 32-bit and 64-bit LabVIEW
v8.5 through 2013) and InstaCal™ installation,
calibration and test utility-powerful solutions for
programmers and nonprogrammers alike. These
modules operate under Microsoft Windows® XP
(32-bit only) and VISTA/7/8 (32-bit and 64-bit)
operating systems.
The OM-USB-2404-UI data acquisition module is
supplied with TracerDAQ software which is a collection
of four virtual instrument applications used to
graphically display and store input data and generate
output signals:
• Strip Chart—Log and graph values acquired from analog inputs, digital inputs, temperature inputs and counter inputs
• Oscilloscope—Display values acquired from analog inputs
• Function Generator—Generate waveforms for analog outputs
• Rate Generator—Generate waveforms for counter outputs
TracerDAQ PRO is an enhanced version of TracerDAQ.
A comparison of some of the features included in
TracerDAQ vs TracerDAQ PRO is shown on the PDF.
SPECIFICATIONS ANALOG INPUT Number of Channels: 4 A/D Converter Resolution: 24-bit A/D Converter Type: Delta-Sigma with analog pre-filtering Sampling Mode: Simultaneous TEDS Sensor Type Supported: IEEE 1451.4 TEDS Class II (interface) Input Mode: Voltage, current, resistance (2- and 4-wire), RTD (3- and 4-wire), thermocouple, quarter-bridge, half-bridge, full-bridge Conversion Time (No channels in TC mode) High Speed: 10 ms for all channels Best 60 Hz Rejection: 110 ms for all channels Best 50 Hz Rejection: 130 ms for all channels High Resolution: 500 ms for all channels Conversion Time (One or More Channels in TC Mode) High Speed: 20 ms for all channels Best 60 Hz Rejection: 120 ms for all channels Best 50 Hz Rejection: 140 ms for all channels High Resolution: 510 ms for all channels Overvoltage Protection Terminals 1 and 2: ±30V Terminals 3 Through 6, Across any Combination: ±60V Input Impedance Voltage Mode (±60V, ±15V, ±4V): 1 MΩ Current Mode: <40 Ω All Other Modes: >1GΩ Input Bias Current: <1nA Integral Non-Linearity (INL): ±15 ppm Common Mode Rejection Ratio (CMRR): >100 dB Normal Mode Rejection Ratio (NMRR) Best 60 Hz Rejection: 90 dB at 60 Hz Best 50 Hz Rejection: 80 dB at 50 Hz High Resolution: 65 dB at 50 Hz and 60 Hz
GENERAL Operating Temperature Range: 0 to 60ºC
(32 to 140ºF), 10 to 90% RH non-condensing Storage Temperature Range: -40 to 85ºC
(-40 to 185ºF), 5 to 95% RH non-condensing Communications: USB 2.0 Hi-Speed mode (480 Mbps)
is recommended; otherwise USB 1.1 full-speed mode
(12 Mbps) Current Consumption from USB: 500 mA, maximum Channel-to-Earth Ground Isolation Continuous: 250 Vrms (measurement category
II for measurements performed on circuits directly
connected to the electrical distribution system) Withstand: 2300 Vrms (verified by a 5 second
dielectric withstand test) Channel-to-Channel Isolation Continuous: 250 Vrms (measurement category
II for measurements performed on circuits directly
connected to the electrical distribution system) Withstand: 1390 Vrms (verified by a 5 second
dielectric withstand test) Signal I/O Connector: 6-position screw terminals Screw terminal Wiring: 18 to 28 AWG copper conductor
wire with 7 mm (0.28") of insulation stripped from the end Maximum Altitude: 2000 m (6562') Dimensions: 134 L x 143 W x 39 mm H (5.27 x 5.64 x 1.54") Weight: 567 g (1.25 lb)
† All amounts shown in EUR, GBP, or USD Note: Comes complete with 2 m (6') USB cable and TracerDAQ software and user manual on CD.