Cookies on the OMEGA websites
We use cookies on this website, these cookies are essential for the website to work correctly.If you continue without changing your settings, we'll assume that you are happy to receive all cookies on this website.To find out more information about these cookies please click here.
CLOSE
Basket  |  Contact  |  Help  | 
Free Phone 0800 488 488
International+44(0) 161 777 6611
Layer N Banner

16-Channel Isolated Analog Signal Conditioning Card for OMB-LOGBOOK-300, OMB-DAQBOARD-2000 Series and OMB-DAQSCAN-2000 Series

OMB-DBK207

16-Channel Isolated Analog Signal Conditioning Card for OMB-LOGBOOK-300, OMB-DAQBOARD-2000 Series and OMB-DAQSCAN-2000 Series | OMB-DBK207

  • Accepts Up to 16 OM5 (5B Compatible) Isolated Analog Input Modules
  • 500 Vdc Channel-to-Channel and Channel-to-System Isolation
  • Modules Can be Mixed in Any Combination to Measure Temperature, Strain, Volts, Current, and Frequency
  • Per-Channel Screw Terminals (14-22 AWG) for Easy Signal Connection, Cold- Junction Sensors for Thermocouple Applications (OMB-DBK207/CJC), and Socket for Current Resistors
  • Up to 16 OMB-DBK207 and/or OMB-DBK207/ CJC Boards Can be Daisy-Chained, Supporting Expansion to 256 Isolated Analog Inputs
  • Requires 5 Vdc Power Supply
  • Optional Rack Mount Kit
  • Easily Configured with DaqView Software (No Programming Required)
Signal Conditioners - View related products

Description

The OMB-DBK207 and OMB-DBK207/CJC signal conditioning and expansion boards can be configured, on a per-channel basis,
with up to 16 isolated OM5 (5B) analog input modules. Both boards feature screw terminals per channel for the convenient connection of field signals as well as sockets for current conversion resistors (supplied with OM5 (5B) current I/O modules, sold separately). The OMB-DBK207/CJC also includes per-channel coldjunction compensation. This allows OM5 (5B) thermocouple modules to output linearized and compensated values eliminating the need for any components apart from a usersupplied thermocouple.

Each user-configurable OM5 (5B) signal conditioning module offers 500 V isolation from the system and from other channels. A wide variety of analog input modules are available for measuring temperature (thermocouple and RTD), strain, volts, current, and frequency.

Up to 16 OMB-DBK207 and/or OMB-DBK207/CJC boards can be daisy-chained (via multiple OMB-CA-37-x cables) providing expansion for up to 256 analog input channels. For applications with both analog and digital I/O channel expansion requirements, the OMB-DBK208 and OMBDBK210 expansion boards are available. All OMB-DBK signal conditioning and expansion boards are scanned at 5 µs/channel.

The OMB-DBK207 and OMB-DBK207/CJC ship with panel-mount hardware but they can also be rack-mounted with the optional rack mounting kit. The OMB-DBK209 and OMBDBK206 adapter boards are used to convert the 100-pin (P4) connector from the
OMB-DAQBOARD-2000 series boards to three expansion ports P1, P2, and P3).

Specifications
Module Capacity: 16, input only, OM5 (5B) compatible modules
Cable: OMB-CA-37-x and OMB-CA-195
DC Input Fuse: 3 A, reset type
Power Requirement: 5 Vdc, regulated
Operating Environment: 0 to 70°C (32 to 158°F)
Relative Humidity: 95% RH non-condensing
Connectors:
P4: 100-pin connector for connection to OMB-DAQBOARD-2000 Series
P4 connector via an OMB-CA-195 cable
P1: 2 P1 (DB37) connectors provide connection to Daq system
P1 and analog expansion via single OMB-CA-37-x cable
or multiple OMB-CA-37-1 cables
Screw Terminals: 16 sets of 4-connector blocks

ISOLATION (DC OR AC PEAK)
Signal Inputs to Daq Device:
500 V
Input Channel-to-Channel: 500 V
CJC: Cold-junction compensation, applicable to OMB-DBK207/CJC board only
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
OMB-DBK207
Consult Sales  
Availability: 
 
 
16-channel isolated analog signal conditioning card
OMB-RACK3
£47.57
Availability: 2 weeks
 
Rack mount kit for OMB-DBK207 and OMB-DBK207/CJC
OM5-LTC-J1-C
Consult Sales  
Availability: 
 
 
Type J thermocouple input module, 0 to 760°C input range, 0 to 5 Vdc output
OM5-LTC-K1-C
Consult Sales  
Availability: 
 
 
Type K thermocouple input module, 0 to 1000°C input range, 0 to 5 Vdc output
OM5-IP-200-C
Consult Sales  
Availability: 
 
 
100 Ohm Pt RTD input module, 0 to 200°C input range, 0 to 5 Vdc output
OM5-IMV-100B-C
Consult Sales  
Availability: 
 
 
Isolated millivolt input module, ±100 mV input range, 0 to 5 Vdc output
OM5-IMV-10B-C
Consult Sales  
Availability: 
 
 
Isolated voltage input module, ±10 Vdc input range, 0 to 5 Vdc output
OMB-CA-195
Consult Sales  
Availability: 
 
 
100-conductor expansion cable for OMB-DAQBOARD-2000, 0.9 m (3') long
OMB-CA-37-1
£66.48
Availability: 2 weeks
 
37-pin single option expansion cable for OMB-DAQSCAN-2000 and OMB-LOGBOOK-300, 18 cm (7') long
All amounts shown in EUR, GBP, or USD
We noticed you are from the US. Visit your local site for regional offers and live support.