Cookies on the OMEGA websites
We use cookies on this website, these cookies are essential for the website to work correctly.If you continue without changing your settings, we'll assume that you are happy to receive all cookies on this website.To find out more information about these cookies please click here.
CLOSE
Basket  |  Contact  |  Help  | 
Free Phone 0800 488 488
International+44(0) 161 777 6611
Layer N Banner

Hygienic RTD Thermowell and Removable Pt100 Sensor with M12 Connector for use in CIP Clean-In-Place Processes

PRS-TW-M12 Series Hygienic RTD Sensors

Hygienic RTD Thermowell and Removable Pt100 Sensor with M12 Connector for use in CIP Clean-In-Place Processes | PRS-TW-M12 Series Hygienic RTD Sensors

£264.32 PRS-3-100-A-TW-0163-D1-M12

  • Clean-In-Place Design for Use in Food, Dairy and Pharmaceutical Processes
  • Standard Mounting Cap is a 1½" 16AMP Tri-GripTM (Tri-Clamp® Compatible) Design, Other Cap Sizes and Styles are Available
  • Removable Probe Assembly is Spring Loaded Into the Thermowell for Good Thermal Response
  • Available with Standard 158, 2½, 4½, 7½, and 10½" Thermowell Immersion Lengths, Other Lengths Available
  • Sensor Includes 4-Wire M12 Connector Plug for Attachment to Process Instrumentation
  • Wetted Surfaces are 316L Stainless Steel, Surface Finish = 32 Microinch or Better
  • 4-Wire, Pt100, Class A Platinum RTD Sensor (100.00 Ω0.06 ± at 0°C) Standard
  • Compatible with 3-Wire and 2-Wire RTD Instruments
Sanitary - View related products

Description

Click on this link if you need more information about Sanitary Sensors.

This Pt100 RTD sensor is designed for use in sanitary or Clean-In-Place (CIP) applications where the use of a thermowell assembly is preferred over direct immersion sensors. The thermowell includes a 1½", 16AMP cap feature for easy installation using industry standard gaskets and clamps. The spring loaded RTD probe can be removed from the thermowell without exposing the system to ambient conditions for calibration or replacement. This sensor includes a 4-Pin, M12 Connector for easy installation using an extension cable.

Sensor Specifications Include:
  • 316L stainless steel process wetted surfaces with surface finishes of 32 microinches or better.

  • Immersion lengths of 158, 2½", 4½", 7½, and 10½" are available from stock, with others available.

  • Sensor Output is a 4-wire, 100 ohm, Class A, Platinum RTD meeting the requirements of IEC 60751.

  • These sensors can be used with 2-wire or 3-wire systems see information below.

  • Insulation resistance values of 100 megohms minimum at 100 VDC.


  • These sensors are supplied standard as 4-wire assemblies with 4-pin connectors.
    When used in 3-wire applications, use pins A, B and C as shown in the wiring detail below.
    When used in 2-wire systems, connect one wire to pins A or B, and the other wire to pins C or D as shown below.

    Wiring Diagram
    Place Order(Specify Model Number)
    Part Number/ Desc.
    Qty
    Description
    PRS-3-100-A-TW-0163-D1-M12
    £264.32
    Availability: 7 weeks
     
    Removable Pt100 RTD sensor with 1½" 16AMP cap, 158" immersion length (U dimension) thermowell, spring loaded with M12 connector
    PRS-3-100-A-TW-0250-D1-M12
    £282.10
    Availability: 7 weeks
     
    Replaceable Pt100 RTD sensor with 1½" 16AMP cap, 2½" immersion length (U dimension) thermowell, spring loaded with M12 connector
    PRS-3-100-A-TW-0450-D1-M12
    £307.51
    Availability: 7 weeks
     
    Replaceable Pt100 RTD sensor with 1½" 16AMP cap, 4½" immersion length (U dimension) thermowell, spring loaded with M12 connector
    PRS-3-100-A-TW-0750-D1-M12
    £356.32
    Availability: 7 weeks
     
    Replaceable Pt100 RTD sensor with 1½" 16AMP cap, 7½" immersion length (U dimension) thermowell, spring loaded with M12 connector
    PRS-3-100-A-TW-1050-D1-M12
    £374.86
    Availability: 7 weeks
     
    Replaceable Pt100 RTD sensor with 1½" 16AMP cap, 10½" immersion length (U dimension) thermowell, spring loaded with M12 connector

    Order By Part Number

    Part Number
    Qty
    Part Number
    Qty


    All amounts shown in EUR, GBP, or USD
    Note: For other cap sizes or styles, other immersion lengths, or for thermistor versions of this product, please contact Sales.

    Ordering Example: (1) PRS-3-100-A-TW-0163-D1-M12 Removable 4-wire Pt100 RTD sensor (100 Ω at 0°C, Class A accuracy) spring loaded in a 1½, £264.32

    Part Number Builder

    Build Your Part Number Below
    Option Descriptions:


    (1) Nominal Element Resistance select from:
    100 for 100 ohm @ 0 C (standard)
    1000 for 1 kohm @ 0 C

    (2) Insertion Length select from:
    0163 for 1-5/8" insertion (2-1/2" well stem length)
    0250 for 2-1/2" insertion (4" well stem length)
    0450 for 4-1/2" insertion (6" well stem length)
    0750 for 7-1/2" insertion (9" well stem length)
    1050 for 10-1/2" insertion (12" well stem length)
    Note: All combinations may not be valid, check spec sheet for valid part numbers.