RTD Probe with Insulated Wire and BX Armored Cable

PR-10-BX

RTD Probe With Insulated Wire And BX Armored Cable
 | PR-10-BX

RTD Probe With Insulated Wire And BX Armored Cable

  • Low temperature range: -50 to 250°C (-58 to 482°F)
  • High temperature range: -50 to 450°C (-58 to 842°F)
  • Extreme temperature range: -200 to 600°C (-328 to 1112°F)
  • Class A accuracy conforming to IEC 60751
  • Standard probe lengths: 2, 3, 4, 6, 9, 12, 18 and 24 in.
  • 2, 3, and 4-wire lead wire styles
  • PT100 and PT1000 RTD element
  • Stripped-end leads with other cold-end termination options
  • Leads covered with BX armored cable
RTD (PT100)  Probes, Elements and Assemblies - View related products

Description

Omega's "BX" armor PT100 or PT1000 RTD probe is designed for resistance to abrasion and snagging in processes where the lead wire is subject to sharp objects, or where the wire is being moved continually. The BX armored cable is placed over PFA wire (for the "Low" temp version and "Extreme" temp version; or fiberglass wire (for the "High" version).
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
PR-10E-3-100-1/4-6-BX
Consult Sales  
Availability: 
 
 
3-wire RTD with BX cable, 6 in. length

This part number has changed. Please see the PR-11-RG Series for the same form, fit, and function.

PR-10E-3-100-1/4-4-120-BX
Consult Sales  
Availability: 
 
 
3-wire RTD with BX cable, 4 in. length

This part number has changed. Please see the PR-11-RG Series for the same form, fit, and function.

PR-10H-3-100-1/4-4-BX
Consult Sales  
Availability: 
 
 
3-wire RTD with BX cable, 4 in. length

This part number has changed. Please see the PR-11-RG Series for the same form, fit, and function.

PR-10H-3-100-1/4-6-BX
Consult Sales  
Availability: 
 
 
3-wire RTD with BX cable, 6 in. length

This part number has changed. Please see the PR-11-RG Series for the same form, fit, and function.

PR-10L-3-100-1/4-6-BX
Consult Sales  
Availability: 
 
 
3-wire RTD with BX cable, 6 in. length

This part number has changed. Please see the PR-11-RG Series for the same form, fit, and function.

PR-10L-3-100-1/8-12-BX
Consult Sales  
Availability: 
 
 
3-wire RTD with BX cable, 12 in. length

This part number has changed. Please see the PR-11-RG Series for the same form, fit, and function.

All amounts shown in EUR, GBP, or USD

Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) RANGE select from:
L for L=LOW (-50 to 250°C)
H for H=HIGH (-50 to 450°C)
E for E=EXTREME (-200 to 600°C)

(2) NUMBER OF WIRES select from:
2 for 2 WIRE
3 for 3 WIRE
4 for 4 WIRE

(3) OHMS select from:
100 for 100 OHMS
1000 for 1000 OHMS

(4) SHEATH DIAMETER select from:
1/8 for 1/8" DIAMETER
3/16 for 3/16" DIAMETER
1/4 for 1/4" DIAMETER

(5) SHEATH LENGTH select from:
2 for 2 INCHES
3 for 3 INCHES
4 for 4 INCHES
6 for 6 INCHES
9 for 9 INCHES
12 for 12 INCHES
18 for 18 INCHES
24 for 24 INCHES

(6) COLD END TERMINATION select from:
Nothing(leave field blank) for stripped leads
-RDXL6SD-CONN for connector for RDXL6SD datalogger
-TA3F for 3-pin DIN connector
-TA4F for 4-pin DIN connector
-HH804-CONNECTOR for DIN connector for use with HH-804 RTD meter
-LUG for Spade Lugs
-MTP for 3-pin mini connector
-OTP for 3-pin standard connector
Note: All combinations may not be valid, check spec sheet for valid part numbers.