Description
The PX209/219 series has been discontinued. Please see the PX309 series as a possible alternative or contact our Technical Sales department.
SPECIFICATIONS Voltage Output Excitation: 24 Vdc @ 15 mA (7 to 35 Vdc for 5 V output, 12 to 35 for 10 V output ) Output: 0 to 5 Vdc or 0 to 10 Vdc ±1.5%(3-wire) Zero Balance: 0 Vdc ±2% FSO 4 to 20 mA Output Excitation: 24 Vdc (7 to 35 Vdc) reverse polarity protected Output: 4 to 20 mA ±1% FSO (2-wire) Zero Balance: 4 mA ±2% FSO Max. Loop Resistance: 50 x (supply voltage -10) Ohms |
Common Specifications Accuracy: 0.25% BFSL (including linearity, hysteresis and repeatability) Operating Temperature: -54 to 121°C (-65 to 250°F) Compensated Temperature: -20 to 80°C (-4 to 176°F) Thermal Effects: 0.04% FS/°C (0.02% FS /°F) Proof Pressure: 150% Burst Pressure: 300% range max. Response Time: 2 mS typical Vibration Sensitivity: At 20 g peak sinusoidal vibration from 10 Hz to 2000 Hz (1.2" D.A.), the output shall not exceed 0.04% FS/g for 15 psi range to 0.005% FS/g for 100 psi and above Natural Frequency: >35 kHz for 100 psi range Gage Type: Diffused silicon strain gages Wetted Parts: 316 SS, borosylicate glass, silicon nitride, epoxy Pressure Port: 1/4-18 NPT Electrical Connections: PX209: 1 m (36") shielded 4-conductor cable PX219: DIN 43650 Plug Connector Supplied Weight: 128 g (4.5 oz) |