Cookies on the OMEGA websites We use cookies on this website, these cookies are essential for the website to work correctly.If you continue without changing your settings, we'll assume that you are happy to receive all cookies on this website.To find out more information about these cookies please click here.
OMEGA’s PX5000 Series pressure transducer has earned a reputation for high performance, reliability and stability in tough, real-world applications. This outstanding transducer uses OMEGA’s advanced sputtered thin-film sensor technology. In the sputtering process, gage material is accelerated in a vacuum chamber toward a sensor substrate, molecule by molecule. They impact with an energy of several thousand electron volts - sufficient to penetrate a few atomic layers and produce the most stable and reliable bond possible. This unique molecular gage bonding provides superior long-term calibration stability and reliability, since the sensors have no cement bonds to degrade with time, or weakened at higher temperatures. The PX5000 transducer excels in tough operating environments. The photo-etched gage pattern makes the sensing element components very small, with short interconnecting leads. This micro-geometry reduces vibration mass, making this transducer much less susceptible to vibration and shock failures and errors. Rugged all-welded construction ensures a durable and reliable instrument. And, this transducer now provides Electrostatic Discharge (ESD) protection to 15kV. You get state-of-the-art thin-film reliability and performance with the PX5000 pressure transducer, yet it is competitively priced. The result is highest value - premium performance without paying a premium price. This transducer is also available with an optional 11 point NIST traceable calibration.
SPECIFICATIONS Excitation: 10 Vdc Output: 30 mV typical, 26 mV minimum Input Resistance: 2000 Ω typical, 800 Ω minimum, 3600 Ω maximum Output Resistance: 2000 ±200 Ω; For 350 ohm bridge see custom configurations Insulation Resistance: 500 MΩ minimum @ 45 Vdc over the compensated range Sensing Element: 4 active-arm bridge using sputter-deposited thin-film elements Accuracy: Combined Linearity, Hysteresis and Nonrepeatability: ±0.10% FSO 0-15 thru 0-999 psi ±0.15% FSO 1,000 psi and above Calibration Stability: ±0.1% for 18 months Reliability: MTBF = 100,000 hours Operating Temp Range: -54 to 150°C (-65 to 300°F) Compensated Temp Range: -54 to 121°C (-65 to 250°F) Thermal Effects: Span: ±0.005% FSO/°F Zero: ±0.005% FSO/°F Vibration Sensitivity: At 35g peak sinusoidal vibration from 10 Hz to 2000 Hz (1/2" D.A.), the output shall not exceed 0.04% FSO/g for 15 psi range to 0.003% FSO/g for 1000 psi and above Natural Frequency: 50 kHz for 5,000 psi range, decreasing logarithmically to 5 kHz for 15 psi range Shock: Qualification level of 100g, 11 msec half sine wave without damage Humidity: Qualified per MIL-STD-810 Electrostatic Discharge (ESD): Protected to 15 kV Pressure: 2.0 times rated pressure or 15,000 psi whichever is less, will no cause changes in performance beyond the specified tolerances Burst Pressure: 3.0 times rated pressure or 20,000 psi whichever is less, will not cause rupture of the pressure containment cavity. Wetted Parts: 17-4 PH Stainless Steel or 15-5 PH Stainless Steel Pressure Fitting: 7/16-20 male per MS33656-4 Mounting Sensitivity: Less than 0.05% FSO change in zero when mounted by the pressure port to a manifold at a torque of 15 ft-lb on a solid copper gasket Mating Connector: PTS06A-10-6S (Not Included) Weight: 5 oz (145g) maximum
Examples of pricing for popular models is referenced in the "To Order" box. Use the "Part Number Builder" below to get pricing for all available models.
† All amounts shown in EUR, GBP, or USD Note: Metric Ranges Available - Consult Engineering
Part Number Builder
Build Your Part Number Below
Option Descriptions:
(1)
Series select from: 5000 for 1000 Ohm Bridge 5003 for 350 Ohm Bridge
(2)
Range (psi) select from: 015 for 0-15 025 for 0-25 050 for 0-50 100 for 0-100 250 for 0-250 500 for 0-500 1K for 0-1000 1.5K for 0-1500 2.5K for 0-2500 3K for 0-3000 5K for 0-5000 10K for 0-10000
(3)
Units select from: G for Gage Pressure S for Sealed Gage Pressure A for Absolute Pressure
(4)
Options select from: for No Options -CAL11 for 11 point NIST traceable calibration
Note: All combinations may not be valid, check spec sheet for valid part numbers.