Very High Accuracy Millivolt Output Transducer With 0-1 Bar to 400 Bar Ranges

PXM01 Series, Metric, mV/V Output

Very High Accuracy Millivolt Output Transducer With 0-1 Bar to 400 Bar Ranges | PXM01 Series, Metric, mV/V Output

  • High Operating Temperature 163°C (325°F)
  • FM Approved Intrinsically Safe
  • 3 mV/V Output
  • All Stainless Steel Construction
  • Shunt Calibration for Fast System Set Up
  • Stainless Steel Construction for Harsh Environments
Pressure Transducers - View related products

Description

Find how a Pressure Transducer works on this link or how we can customize your Pressure Sensor.

OMEGA’s PXM01 Series is a very high accuracy, 30 millivolt output, industrial pressure transducer. The all stainless steel construction makes it suitable for harsh industrial environments. FM approved intrinsically safe is standard. The PXM01 has a high operating range, a broad compensated range and excellent temperature compensation which gives stable readings in harsh applications. They are available in gauge, sealed gauge or absolute models as well as bar or psi ranges. G-1/8 or G-1/4 pressure fittings are available as well as connector or cable electrical terminations

SPECIFICATIONS
Excitation:
10 Vdc (15Vdc max)
Output: 3 mV/V ±0.25%
Input Resistance: 350 .±10 Ohms
Output Resistance: 350 .±10 Ohms
Zero Balance: 1.0% FS
Linearity: ±0.05% FS
Hysteresis: ±0.05% FS
Repeatability: ±0.05% FS
Agency Approvals: Standard FM Intrinsically Safe IS/I.II.III/1/CDEFG
Shunt Calibration: Value specified on Calibration sheet
Sensing Element: 4 active-arm bridge, using thick film strain gauges in a hermetically sealed chamber
Operating Temp Range: -73 to 163°C (-100 to 325°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Span:
0.0027% Rdg/°C
Zero: 0.0027% FS/°C
Proof Pressure: 150% of rated pressure
Burst Pressure: 300% of rated pressure
Wetted Parts: 17-4PH SS
Pressure Port: G 1/4 Male/Female or G 1/8 Male/Female
Electrical Connections:
Style "0" = 3 m cable
Style "1" = PTIH-10-6P connector
Style "6" = micro DIN
Mating Connector:
Style "1" = PT06F-10-6S (not included)
Style "6" = included
Weight: 170 g (6 oz)

For special options consult Sales or Pressure Engineering.

Most Popular models are featured in the "Place Order" below.
For the full selection of all models available, see the "Part Number Builder" below the "Place Order" table.
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
PXM01MD0-001BARGV
Consult Sales  
Availability: 
 
 
Metric transducer with 0-1 Bar gauge pressure range, 30 mVdc output, G 1/4 female fitting and 3 meter cable
PXM01MD0-1.60BARGV
Consult Sales  
Availability: 
 
 
Metric transducer with 0-1.6 Bar gauge pressure range, 30 mVdc output, G 1/4 female fitting and 3 meter cable
PXM01MD0-2.50BARGV
Consult Sales  
Availability: 
 
 
Metric transducer with 0-2.5 Bar gauge pressure range, 30 mVdc output, G 1/4 female fitting and 3 meter cable
PXM01MD0-004BARGV
Consult Sales  
Availability: 
 
 
Metric transducer with 0-4 Bar gauge pressure range, 30 mVdc output, G 1/4 female fitting and 3 meter cable
PXM01MD0-006BARGV
Consult Sales  
Availability: 
 
 
Metric transducer with 0-6 Bar gauge pressure range, 30 mVdc output, G 1/4 female fitting and 3 meter cable
PXM01MD0-010BARGV
Consult Sales  
Availability: 
 
 
Metric transducer with 0-10 Bar gauge pressure range, 30 mVdc output, G 1/4 female fitting and 3 meter cable
PXM01MD0-016BARGV
Consult Sales  
Availability: 
 
 
Metric transducer with 0-16 Bar gauge pressure range, 30 mVdc output, G 1/4 female fitting and 3 meter cable
PXM01MD0-025BARGV
Consult Sales  
Availability: 
 
 
Metric transducer with 0-25 Bar gauge pressure range, 30 mVdc output, G 1/4 female fitting and 3 meter cable
PXM01MD0-040BARGV
Consult Sales  
Availability: 
 
 
Metric transducer with 0-40 Bar gauge pressure range, 30 mVdc output, G 1/4 female fitting and 3 meter cable
PXM01MD0-060BARGV
Consult Sales  
Availability: 
 
 
Metric transducer with 0-60 Bar gauge pressure range, 30 mVdc output, G 1/4 female fitting and 3 meter cable
PXM01MD0-100BARGV
Consult Sales  
Availability: 
 
 
Metric transducer with 0-100 Bar gauge pressure range, 30 mVdc output, G 1/4 female fitting and 3 meter cable
PXM01MD0-160BARGV
Consult Sales  
Availability: 
 
 
Metric transducer with 0-160 Bar gauge pressure range, 30 mVdc output, G 1/4 female fitting and 3 meter cable
PXM01MD0-250BARGV
£913.29
Availability: 18 weeks
 
Metric transducer with 0-250 Bar gauge pressure range, 30 mVdc output, G 1/4 female fitting and 3 meter cable
PXM01MD0-400BARGV
Consult Sales  
Availability: 
 
 
Metric transducer with 0-400 Bar gauge pressure range, 30 mVdc output, G 1/4 female fitting and 3 meter cable
All amounts shown in EUR, GBP, or USD
Note: 0-160 mBar and 0-400 mBar ranges are available on models with amplified outputs only.

Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Pressure Fitting select from:
MA for G 1/8 male
MB for G 1/8 female
MC for G 1/4 male
MD for G 1/4 female

(2) Electrical Termination select from:
0 for 3 meter cable
1 for PT1H-10-6P connector (mating connector sold separately)
5 for Lightening protected amplifier box (4-20 ma only)
6 for micro DIN connector (no shunt cal)

(3) Pressure Range select from:
160M for 0-160 mBar
400M for 0-400 mBar
001 for 0-1 Bar
1.60 for 0-1.6 Bar
2.50 for 0-2.5 Bar
004 for 0-4 Bar
006 for 0-6 Bar
010 for 0-10 Bar
016 for 0-16 Bar
025 for 0-25 Bar
040 for 0-40 Bar
060 for 0-60 Bar
100 for 0-100 Bar
160 for 0-160 Bar
250 for 0-250 Bar
400 for 0-400 Bar

(4) Units select from:
A for Absolute Pressure
G for Gauge Pressure
S for Sealed Gauge Pressure

(5) Output select from:
V for mV/V Output
5E for Isolated 0-5 Volt Output
10E for 0-10 Volt Output
I for 4-20 mA Output
Note: All combinations may not be valid, check spec sheet for valid part numbers.