Option Descriptions:
(1)
Electrical Termination select from:PXM409S for 2 m (6 ft) vented cable
PXM409CS for conduit fitting with 2m vented cable
PXM419S for mini DIN
PXM429S for Twist-Lock connector
PXM459S for M12 Connector
(2)
Process Fitting select from:15 for 1.5 inch Tri-Grip
20 for 2 inch Tri-Grip (500 psi max)
(3)
Range select from:025H for 0 to 25 mbar
070H for 0 to 70 mbar
170H for 0 to 170 mbar
350H for 0 to 350 mbar
001B for 0 to 1 bar
002B for 0 to 2 bar
3.5B for 0 to 3.5 bar
007B for 0 to 7 bar
010B for 0 to 10 bar
17.5B for 0 to 17.5bar
035B for 0 to 35bar
040B for 0 to 40 bar (1.5 inch Tri-Grip only)
1100 for 0 to 1100 mbar (Barometric Only)
550 for 550 to 1100 mbar (Barometric Only)
880 for 880 to 1100 mbar (Barometric Only)
(4)
Pressure Type select from:G for Gauge pressure
CG for Compound Gauge Pressure (±25 mb to ±1 bar Ranges)
SG for Hermetically Sealed Gauge (PXM429 and Ranges >=7 bar )
A for Absolute pressure (350 mb to 40 bar)
V for Gauge Vacuum (-25mbar to -1bar Ranges)
HB for Barometric Pressure only
(5)
Output Type select from:V for 10 mV/V
5V for 0 to 5 Vdc
10V for 0 to 10 Vdc
I for 4 to 20 mA (zero set to 12 mA for compound gauge ranges)
Note: All combinations may not be valid, check spec sheet for valid part numbers.