Retractable Sensor Cables for Thermocouples, RTDs and Thermistors

RSC and RSCM Series

Retractable Sensor Cables for Thermocouples, RTDs and Thermistors | RSC and RSCM Series

£10.05 RSC-RTD-1-0-0

  • J, K, T and E Thermocouple Calibrations and 3-Wire Copper for RTD’s and Thermistors
  • Expansion Ratio up to 500%, 300 mm of Cable Stretches to 1.5 metres
  • TPE Plastic Insulation for Indoor and Outdoor Use to 100°C
  • Retracted Coil Lengths of 30, 60, 90 and 120 cm with 150 mm Straight Ends
Wire: Thermocouple, RTD, Thermistor and Hook-Up - View related products

Description

Retractable Sensor Cable is colour coded and spring coiled, for use with thermocouples, RTD’s and thermistors.

To achieve a superior jacket construction, OMEGA has employed the latest in insulating material: TPE (thermoplastic elastomer), a unique family of thermoplastics which exhibits characteristics previously found only in rubber compounds. TPE is extremely tough and flexible, and has excellent abrasion resistance. Our special construction technique yields an expansion rate of up to 500%.

OMEGA’s retractable sensor cables are specifically recommended for use with electronic-type indicators, either panel, handheld or bench type models. Retractable sensor cables have hundreds of applications: oscillating machinery, handheld surface probes, or wherever retractable sensor cables are required.

Colour Code of Cables and Alloys Used
Cable Type Conductor Alloys ANSI Colour Code IEC Colour Code
Jacket +Insulation –Insulation Jacket +Insulation –Insulation
JIron/ConstantanBlackWhiteRedBlackBlackWhite
KChromel/AlumelYellowYellowRedGreenGreenWhite
TCopper/ConstantanBlueBlueRedBrownBrownWhite
EChromel/ConstantanPurplePurpleRedPurplePurpleWhite
RTD/THCopper (3-Wire)White2 Black 1 RedWhite2 Black 1 Red


Typical Resistance of Cables
Ohms Per 30 cm of Coiled (150 cm Extended) Cable
JKTERTD and Thermistor (per Conductor)
16.327.51433.10.57


Cable End Termination Options
Reference Description
0 25 mm Stripped Ends
1 Compensated Spade Lugs
2 Standard Thermocouple Plug (OSTW-M)
3 Standard Thermocouple Socket (OSTW-F)
4 Mini Thermocouple Plug (SMPW-M)
5 Mini Thermocouple Socket (SMPW-F)
6 RTD 3-pin Standard Socket (OTP-F)
7 RTD 3-pin Standard Plug (OTP-M)
8† RTD 3-pin Round Socket (TA3-FL)
9† RTD 3-pin Round Plug (TA3-ML)
10 RTD 3-pin Mini Socket (MTP-F)
11 RTD 3-pin Mini Plug (MTP-M)


Model No. Input
Type
O.D.
mm
RSC-(1)-(2)-(3)-(4)T/C4.2 mm
RSC-RTD-(2)-(3)-(4)RTD4.4 mm
RSC-TH-(2)-(3)-(4)TH4.4 mm
RSCM*-(1)-(2)-(3)-(4)T/C3.4 mm
How To Order
1. Fill the 1st box (1) with desired thermocouple type and colour code. Use symbols “JI”, “KI”, “TI”, “EI” for IEC Colour-coded thermocouple types, “J”, “K”, “T”, “E” for ANSI colour-coded thermocouple types; “RTD” for RTD/Pt100/Pt1000; or “TH” for thermistor.
2. Fill in 2nd box (2) with retracted coil length: 1 = 30cm, 2 = 60cm, 3 = 90cm, 4 = 1.2m
3. Fill in 3rd box (3) with termination style number (one end).
4. Fill in 4th box (4) with termination style number (other end).

* M = Miniature Retractable Cable
† Indicate associated meter or pin out desired for connector
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
IEC Colour coded thermocouple standard extension cables
RSC-KI-30-0-0
£12.08
Availability: 7 weeks
 
Type K, 30cm with stripped ends
RSC-KI-30-4-4
£25.95
Availability: 7 weeks
 
Type K, 30cm with mini plugs at both ends
RSC-KI-30-4-5
£25.83
Availability: 7 weeks
 
Type K, 30cm with mini plug one end and mini socket at the other end
RSC-KI-60-4-5
£33.76
Availability: 7 weeks
 
Type K, 60cm with mini plug one end and mini socket at the other end
RSC-KI-90-4-5
£38.79
Availability: 7 weeks
 
Type K, 90cm with mini plug one end and mini socket at the other end
RSC-TI-30-4-5
Consult Sales  
Availability: 
 
 
Type T, 30cm with mini plug one end and mini socket at the other end
RSC-TI-90-4-5
Consult Sales  
Availability: 
 
 
Type T, 90cm with mini plug one end and mini socket at the other end
IEC Colour coded thermocouple miniature extension cables
RSCM-KI-30-0-0
Consult Sales  
Availability: 
 
 
Type K, 30cm with stripped ends
RSCM-KI-30-4-5
£27.69
Availability: 7 weeks
 
Type K, 30cm with mini plug one end and mini socket at the other end
RSCM-KI-60-4-5
£33.76
Availability: 7 weeks
 
Type K, 60cm with mini plug one end and mini socket at the other end
RSCM-KI-120-4-5
Consult Sales  
Availability: 
 
 
Type K, 120cm with mini plug one end and mini socket at the other end
All amounts shown in EUR, GBP, or USD
Ordering Example: (1) RSC-KI-30-4-5 Type K IEC colour-coded retractable sensor cable, 30cm long with a mini thermocouple plug at one end and a mini socket at the other end, £25.83

Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Cable Type select from:
RSC for Retractable sensor cable
RSCM for Miniature retractable sensor cable

(2) Input Type select from:
JI for Type J IEC colour-code thermocouple
KI for Type K IEC colour-code thermocouple
TI for Type T IEC colour-code thermocouple
EI for Type E IEC colour-code thermocouple
J for Type J ANSI colour-code thermocouple
K for Type K ANSI colour-code thermocouple
T for Type T ANSI colour-code thermocouple
E for Type E ANSI colour-code thermocouple
RTD for Resistance temperature dector
TH for Thermistor

(3) Retracted Length select from:
30 for 30 cm (IEC only)
60 for 60 cm (IEC only)
90 for 90 cm (IEC only)
120 for 120 cm (IEC only)
1 for 1 ft (ANSI only).
2 for 2 ft (ANSI only)
3 for 3 ft (ANSI only)
4 for 4 ft (ANSI only)

(4) Termination Style (End #1) select from:
0 for Trimmed Ends(standard)
1 for Spade Lugs
2 for OST-M(Male)
3 for OST-F(Female)
4 for SMP-M(Male)
5 for SMP-F(Female)
6 for OTP-F(Female-Thermistor and RTD only)
7 for OTP-M(Male-Thermistor and RTD only)
8 for TA3-FL(Female-Thermistor and RTD only)
9 for TA3-ML(Male-Thermistor and RTD only)
10 for MTP-F(Female-Thermistor and RTD only)
11 for MTP-M(Male-Thermistor and RTD only)

(5) Termination Style (End #2) select from:
0 for Trimmed Ends(standard)
1 for Spade Lugs
2 for OST-M(Male)
3 for OST-F(Female)
4 for SMP-M(Male)
5 for SMP-F(Female)
6 for OTP-F(Female-Thermistor and RTD only)
7 for OTP-M(Male-Thermistor and RTD only)
8 for TA3-FL(Female-Thermistor and RTD only)
9 for TA3-ML(Male-Thermistor and RTD only)
10 for MTP-F(Female-Thermistor and RTD only)
11 for MTP-M(Male-Thermistor and RTD only)
Note: All combinations may not be valid, check spec sheet for valid part numbers.