Fine Diameter Thermocouple (0.25 mm - 1 mm) Transition Junction TC Probes with Lead Wire

TJ36 Series in Fine Diameter

Fine Diameter Thermocouple Probes with pot seal and lead wire | TJ36 Series in Fine Diameter

£46.04 TJ36-CASS-032G-6

  • Fine-Diameter Probes as Small as 0.25 mm (0.10 in.)
  • Probes are Available in K, N, J and T Calibrations
  • 304 SS and Inconel® 600. Also available with Super Omegaclad® XL Sheath!
  • 1m (40 in.) Stripped PFA-Insulated Lead Wire Rated to 260° C (500°F)
  • Spring Strain Relief Prevents "Pinching" of the Wire
  • Manufactured with OMEGACLAD™ Compacted Mineral Insulation Cable for Long-Lasting, Low-Drift Performance in Harsh Conditions
Thermocouples - View related products

Description

Calibration
ANSI Code
Sheath Material Sheath Dia.
mm (in.)
Upper Temp. Limits
T/C Junct.
°C (°F)
Model Number
(See Notes Below)
K
Chromel-
Alumel
304 SS 0.25 (0.010)
0.50 (0.020)
0.80 (0.032)
1.0 (0.040)
260 (500)
371 (700)
371 (700)
371 (700)
TJ36-CASS-010(*)-(**)
TJ36-CASS-020(*)-(**)
TJ36-CASS-032(*)-(**)
TJ36-CASS-040(*)-(**)
Inconel®
600
0.25 (0.010)
0.50 (0.020)
0.80 (0.032)
1.0 (0.040)
260 (500)
371 (700)
371 (700)
371 (700)
TJ36-CAIN-010(*)-(**)
TJ36-CAIN-020(*)-(**)
TJ36-CAIN-032(*)-(**)
TJ36-CAIN-040(*)-(**)
Super
OMEGACLAD™
XL
0.25 (0.010)
0.50 (0.020)
0.80 (0.032)
1.0 (0.040)
316 (600)
427 (800)
815 (1500)
815 (1500)
TJ36-CAXL-010(*)-(**)
TJ36-CAXL-020(*)-(**)
TJ36-CAXL-032(*)-(**)
TJ36-CAXL-040(*)-(**)
J
Iron-
Constantan
304 SS 0.25 (0.010)
0.50 (0.020)
0.80 (0.032)
1.0 (0.040)
204 (400)
260 (500)
260 (500)
260 (500)
TJ36-ICSS-010(*)-(**)
TJ36-ICSS-020(*)-(**)
TJ36-ICSS-032(*)-(**)
TJ36-ICSS-040(*)-(**)
T
Copper-
Constantan
304 SS 0.50 (0.020)
0.80 (0.032)
1.0 (0.040)
260 (500)
260 (500)
260 (500)
TJ36-CPSS-020(*)-(**)
TJ36-CPSS-032(*)-(**)
TJ36-CPSS-040(*)-(**)
Notes: *Specify Junction: (G)rounded, (E)xposed or (U)ngrounded.
**Specify length in inches: 6 for 150 mm (6 in.), 12 for 300 mm (12 in.), or 18 for 450 mm (18 in.).
Super OMEGACLAD™ XL probes (highlighted in yellow) are also available in N calibration; substitute TJ36-NNXL for TJ36-CAXL in Model Number.

View the Thermocouple Accuracy and Color Code charts
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
0.25 mm Diameter Thermocouples
TJ36-CASS-010G-6
£81.05
Availability: 2 weeks
 
Type K with 150 mm long 304 SS Sheath, 0.25 mm and grounded junction
TJ36-CASS-010G-12
£81.05
Availability: 2 weeks
 
Type K with 300 mm long 304 SS Sheath, 0.25 mm and grounded junction
TJ36-CASS-010U-6
£112.58
Availability: 9 weeks
 
Type K with 150 mm long 304 SS Sheath, 0.25 mm and insulated junction
0.5 mm Diameter Thermocouples
TJ36-CASS-020G-6
£46.04
Availability: 2 weeks
 
Type K with 150 mm long 304 SS Sheath, 0.5 mm and grounded junction
TJ36-CASS-020U-6
£47.85
Availability: 9 weeks
 
Type K with 150 mm long 304 SS Sheath, 0.5 mm and insulated junction
0.8 mm Diameter Thermocouples
TJ36-CAIN-032U-6
£48.73
Availability: 9 weeks
 
Type K with 150 mm long Inconel Sheath, 0.8 mm and insulated junction
TJ36-CAXL-032U-12
£53.57
Availability: 9 weeks
 
Type K with 300 mm long SuperOmegaclad XL Sheath, 0.8 mm and insulated junction
1 mm Diameter Thermocouples
TJ36-CASS-040U-6
£47.85
Availability: 9 weeks
 
Type K with 150 mm long 304 SS Sheath, 1 mm and insulated junction
TJ36-CASS-040G-12
£57.30
Availability: 2 weeks
 
Type K with 300 mm long 304 SS Sheath, 1 mm and grounded junction
All amounts shown in EUR, GBP, or USD
Note: Additional PFA Lead wire and probe lengths are also available; contact Sales.

Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Lead Wire Length select from:
36 for 1 metre (40 in)
CUSTOM for custom length in inches(whole number only up to 600 inches max)

(2) Thermocouple Type select from:
CA for Type K
CX for Type E
IC for Type J
CP for Type T (Not available with 010 diameter)
NN for Type N (Only available with XL and IN sheath)

(3) Sheath Material select from:
SS for 304 SS
IN for Inconel®
XL for Super OMEGACLAD™ XL (Only available with Thermocouple Type K and N)

(4) Probe Diameter select from:
010 for 0.010 in. (0.25 mm)
020 for 0.020 in. (0.50 mm)
032 for 0.032 in. (0.80 mm)
040 for 0.040 in. (1.00 mm)

(5) Junction Type select from:
E for Exposed
G for Grounded
U for Insulated

(6) Length select from:
6 for 6 in. (150 mm)
12 for 12 in. (300 mm)
CUSTOM for custom length in inches(whole numbers only from 2 to 120 inches)
Note: All combinations may not be valid, check spec sheet for valid part numbers.
We noticed you are from the US. Visit your local site for regional offers and live support.