Food Equipment Heaters

TTUH Series

Food Equipment Heaters | TTUH Series

Food Equipment Heaters

£386.11 TTUH-10A/120V

  • TTUH-CO Series
    • Brass Flange
    • Copper Sheath
    • High Watt Density
    • Without Contactor
    • Integral Low Liquid Thermal Cutout
  • TTUH Series
    • High Watt Density
    • Brass Flange
    • Copper Sheath
    • Without Integral Low-Liquid Cutout
    • Bottom Mounted
Immersion Heaters - View related products

Description

Find how a Immersion Heater works on this link or general information about industrial heater elements.

FEATURES

The TTUH-CO series heater is mounted through a 27/16" dia. (6 cm) opening in bottom of vessel. Heater is inserted with gasket through top of vessel or through hand hole. Mount combination terminal box and clamp over the element flange and use bolt to draw mounting clamp tightly to the tank. When mounting in a closed tank, a hand hole should be cut in the side of the tank only large enough to insert the heater and reach to the bottom of the tank to insert in the 27/16" dia. (6 cm) mounting hole. See To Order table for heater dimensions.

The type TTUH heater is mounted through a 27/16 " dia. (6 cm) opening in bottom of vessel. Heater is inserted with gasket through top of vessel or through hand hole. Mount combination terminal box and clamp over the elements flange and use bolt to draw mounting clamp tightly to tank. When mounting in a closed tank, a hand hole should be cut in the side of the tank only large enough to insert the heater and reach to the bottom of the tank to insert in the 27/16 " dia. (6 cm) mounting hole. See To Order Table for heater dimensions.

CAUTION AND WARNING!
Fire and electrical shock may result if products are used improperly or installed or used by non-qualified personnel. See inside back cover for additional warnings.

TTUH-CO Series


Model No. kW W/in2 Dimensions Inches (cm) Wt.
Ib. (kg)
A B C D
TTUH-CO Series — Single Phase W/cutout — 2 1/2" Minimum Liquid Depth
TTUH-CO-15/*1.5627 7/16 (19)4 13/16 (12)31/16(8)2 3/8 (6)3 (1)
TTUH-CO-20/*2609 7/16 (23)4 13/16 (12)31/16 (8)2 1/8 (5)3 (1)
TTUH-CO-25/*2.5406 3/4(17)4 13/16 (12)31/16(8)2 1/8(5)31/8(1)
TTUH-CO-30/*3556 3/4 (17)4 13/16 (12)31/16(8)2 1/8 (5)31/4 (1)
TTUH-CO-40/*4649 1/2(24)4 13/16 (12)31/16 (8)2 1/8(5)37/8 (2)
TTUH-CO-50/*57012 3/4(32)5 3/8 (14)4 (10)2 11/16 (7)5 (2)
TTUH-CO-60/*67314 1/2 (37)5 3/8 (14)4 (10)2 11/16 (7)6 (3)
TTUH-CO-70/240V78514 1/2( 37)5 3/8 (14)4 (10)2 11/16 (7)6 (3)
TTUH-CO Series — Three Phase with Cutout — 3" Minimum Liquid Depth
TTUH-CO-303/*/3P3558 3/4(22)5 11/16(15)31/8 (8)2 3/4 (7)4 (2)
TTUH-CO-403/*/3P4748 3/4 (22)5 13/16(15)31/8 (8)2 3/4(7)5 (2)
TTUH-CO-503/**/3P57311 (28)5 13/16(15)31/8 (8)2 3/4 (7)5 (2)
TTUH-CO-603/*/3P67211 1/16 (28)5 3/4(16)41/16(10)3(8)5 (2)
TTUH-CO-703/208V/3P77811 1/16 (28)5 3/4 (16)41/16(10)3(8)41/2 (2)
TTUH-CO-803/208V/3P86914 1/2 (37)5 3/4(16)41/16(10)3(8)6 (3)
TTUH-CO-903/208V/3P97814 1/2 (37)5 3/ (16)41/16(10)3 (8)6 (3)
*Designate voltage, i.e., 120 for 120 VAC, 208 for 208 VAC or 240 for 240 V, or 480 for 480 V.
Other kW rating and voltages are available. Contact OMEGALUX™.

TTUH Series


Model No. kW W/in2 Dimensions Inches (cm) Wt.
Ib. (kg)
A B C D
TTUH Series — 1 Phase w/o Cutout, 2" Min. Liquid Depth
TTUH-10A/120V1426 3/4 (17)4 9/16 (12)4 1/4 (8)2 5/16 (6)2 3/4 (1)
TTUH-15A/*1.5576 3/4 (17)4 9/16 (12)4 1/4 (8)2 5/16 (5)2 3/4 (1)
TTUH-20A/*2576 3/4 (17)4 9/16 (12)4 1/4 (8)2 5/16 (5)2 3/4 (1)
TTUH-25A/*2.5586 3/4 (17)4 9/16 (12)4 1/4 (8)2 5/16 (5)2 7/8 (1)
TTUH-30A/*3556 3/4 (17)4 9/16 (12)4 1/4 (8)2 5/16 (5)3 (2)
TTUH-40A/*4539 1/2 (24)4 9/16 (14)4 (10)1 3/8 (7)3 7/8 (2)
TTUH-50/**53912 3/4 (32)4 9/16 (14)4 (10)1 11/16 (7)4 1/2 (3)
TTUH-60/**64214 1/2 (37)4 9/16 (15)4 (10)1 11/16 (7)5 1/2 (3)
TTUH-70/**74914 1/2 (37)4 9/16 (14)4 (10)1 11/16(7)5 1/2 (3)
TTUH Series — 3 Phase w/o Cutout 3" Minimum Liquid Depth
TTUH-303/208V/3P3558 3/4 (22)4 5/8 (15)3 1/8 (8)1 15/16 (7)3 1/2 (2)
TTUH-303/240V/3P3558 3/4 (22)4 5/8 (15)3 1/8 (8)1 15/16 (7)3 1/2 (2)
TTUH-403/208V/3P4748 3/4 (22)4 5/8 (15)3 1/8 (8)1 15/16 (7)3 1/2 (2)
TTUH-403/240V/3P4748 3/4 (22)4 5/8 (16)3 1/8 (10)1 15/16 (8)3 1/2 (2)
TTUH-403/480V/3P4748 3/4 (22)4 5/8 (16)3 1/8 (10)1 15/16 (8)3 1/2 (2)
TTUH-503/**/3P57311 (28)4 5/8 (16)3 1/8 (10)1 15/16 (8)3 1/2 (2)
TTUH-603/240V/3P66711 1/16 (28)5 (16)4 1/16 (10)2 3/8 (8)4 1/2 (3)
TTUH-603/480V/3P66711 1/16(28)5(16)4 1/16 (10)2 3/8 (8)4 1/2 (3)
TTUH-703/**/3P77811 1/16(28)5(16)4 1/16 (10)2 3/8 (8)4 1/2 (3)
TTUH-803/**/3P86911 1/8(28)5(16)4 1/16 (10)2 3/8 (8)4 1/2 (3)
TTUH-1203/240V/3P129817 3/4 (45)5(16)4 1/16 (10)2 3/8 (8)5 1/2 (3)
†Minimum liquid level should be maintained at 1/2" (1.27 cm) above D Dimension
/* Designate voltage, i.e., insert 120 for 120V, 240 for 240 V or 480 V.
/** Designate voltage, i.e., insert 208 for 208 V 240 for 240 V


Not all combinations may be vaild in the "Part Number Builder".
Please review the spec sheet for all possible valid part numbers.
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
Example part numbers are shown below. For additional configurations see the Part Number Builder below this table.
TTUH-15A/120V
£397.61
Availability: 6 weeks
 
1.5 kW heater powered by 120 Vac
All amounts shown in EUR, GBP, or USD

Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Low Liquid Cutout select from:
Nothing(leave field blank)
-CO for with low liquid cutout

(2) kW select from:
10 for 1 kW
15 for 1.5 kW
20 for 2 kW
25 for 2.5 kW
30 for 3 kW
40 for 4 kW
50 for 5 kW
60 for 6 kW
70 for 7 kW
303 for 3 kW
403 for 4 kW
503 for 5 kW
603 for 6 kW
703 for 7 kW
803 for 8 kW
903 for 9 kW
1203 for 12 kW

(3) VAC select from:
/120V for 120 VAC
/208V for 208 VAC
/240V for 240 VAC
/480V for 480 VAC

(4) Phase select from:
Nothing(leave field blank)
/3P for 3 phase
Note: All combinations may not be valid, check spec sheet for valid part numbers.