Basket  |  Contact  |  Help  | 
Free Phone 0800 488 488
International+44(0) 161 777 6611
Layer N Banner

DIN Rail Mount Signal Conditioner. RTD, Thermocouple, Resistance, mV, Silicon Sensor & Slidewire Inputs

TXDIN1600T

Smart signal conditioner | TXDIN1600T

Smart signal conditioner

£124.78 TXDIN1600T

5 year warranty
  • Accepts RTD, Thermocouple and Slidewire Sensors
  • Current (Active or Passive), Voltage Or Bipolar Voltage Output
  • Powered ( 10 to 32) V AC / (10 to 48) V DC Supply
  • 22 Segment User Linearisation
  • Sensor Offset and Output Alignment
  • Adjustable Input Filter
Signal Conditioners - View related products

Description

The TXDIN1600T DIN Rail Transmitter is designed for all common thermocouples (13 types) and resistive temperature detectors in the range of 10 to 10k5 Ω. The 3-way galvanic isolation allows for a number of transmitters to be powered from the same power supply and enables the use of non-isolated thermocouples for fast temperature response, or thermocouples which are at a high voltage potential.

The flexible output circuit has voltage, bipolar voltage or mA signals, allowing simple, direct wiring to controllers, indicators, PLCs or PC-measuring systems.

22 point user linearisation is available for slide-wire, mV or linear resistance inputs and the output signal is fully scalable. A 0-100s digital filter is also available, making the TXDIN1600T suitable for many different measurement applications.

The mini Type-B USB socket allows direct connection to a suitable PC for quick and easy configuration using the free software.

Specifications

 

Thermocouple/mV

Type

Range

Standard

Accuracy at 20°C

Basic Accuracy

Thermal Drift

J (Fe-CuNi)

-100 to +1200°C

IEC 584: 1998-06

< ±0.5°C, ±0.1% FS

Offset 0.1°C/°C,

Span 0.05°C/°C

K (NiCr-Ni)

-200 to +1370°C

L (Fe-CuNi)

-100 to +600°C

DIN 43760: 1985-12

E (NiC-Cu)

-200 to +1000°C

IEC 584: 1998-06

T (Cu-CuNi)

-200 to +400°C

< ±0.5°C, ±0.2% FS

N (NiCrSi-NiSi)

-180 to +1300°C

< ±0.5°C, ±0.1% FS

U (Cu-CuNi)

0 to +600°C

DIN 43760: 1985-12

R (PtRh-Pt)

0 to +1760°C

IEC 584: 1998-06

S (PtRh-Pt)

0 to +1760°C

B (PtRh-Pt)

0 to +1800°C

C

0 to +2300°C

ASTM E988

D

G

mV

-100 to 200 mV

 

± 0.02% of full scale

 

Cold Junction Range: -40 to +85°C; Accuracy: ±0.2°C; Drift: ±0.05°C/°C

RTD and Resistance

Type

Range

Standard

Curve

Accuracy at 20°C

Pt100

-200 to 850°C

DIN EN 60751: 1996

α = 0.00385

< ±0.2°C, ±0.05% Reading

Pt500

-200 to 750°C

Pt1000

-200 to 600°C

JPt100

-200 to 630°C

JIS C 1606: 1989

α = 0.003916

Cu100

-80 to 260°C

 

α = 0.00427

Cu1000

-80 to 260°C

   

Ni100

-60 to 180°C

DIN 43760: 1987

α = 0.00618

Ni120

-80 to 260°C

α = 0.00672

Ni1000

-50 to 150°C

 

Tk5000

Ni507.5

-80 to 360°C

   

Ni604

-200 to 200°C

   

Cu53

-50 to 180°C

   

Silicon sensor

-55 to 175°C

KTY81-110 -120-121-122-150-210-220-221-222-250

KTY82-110 -120-121-122-150-210-220-221-222-250

KTY81-151

KTY82-151

KTY83-210-220-250-121-122

-40 to 300°C 

KTY84-130-150

 
Potentiometer and Slide-wire

Sensor

Range 

Accuracy

Thermal Drift

Potentiometer

1 to 100 kΩ

0.1%

 

Slide-wire

10 to 500 Ω

± 0.055 Ω

0.013 Ω/°C

500 to 2500 Ω

± 0.5 Ω

0.063 Ω/°C

2500 to 10500 Ω

± 10 Ω

0.27 Ω/°C

Measuring Current: < 200 μA
Max. Lead Resistance: 20 Ω per leg; Effect: 0.002°C/Ω

Output Current
Current Source: Range (0 to 21.5) mA , Max. Load 750 Ω
Current Sink:
Range (0 to 21.5) mA , Supply (10 to 30) V dc, Voltage effect 0.2 uA/V
Accuracy: (mA Out/ 2000) or 5 uA whichever is the greater, Drift 1 uA/°C

Output Voltage
Range: (0 to 10.1) V or (-10.1 to 10.1) V, Accuracy ± 5 mV
Current Drive: ± 2 mA, Min. load 5000 Ω @ 10 V

Power Supply
Range: (10 to 48) Vdc, (10 to 32) Vac
Protection:
Internal 500 mA resettable fuse
Power:
< 1W Full Power

General
Response time: Start up 5 seconds, Update 300 mS, Response 400 mS, Warm up 2 minutes.
Galvanic Isolation: Supply to input to output 500 V dc.
LED Indication (STATE):
LED, Green when output (-0.1 to 100.1) %, else red LED, Red = input / output error

User Interface
Type: USB 2.0
Equipment:
PC running windows XP or later, USB cable.

 

User Interface Functions
Scaling: User signal to process value scaling, for simplified setup.
Filter: Adjustable time constant (0 to 100) Seconds.
User Linearisation (Profile): (2 to 22) segments Ω (slide wire) and mV to process.
Process Units: 4 Characters (signal input only)
Temperature units: °C or °F (TC, RTD inputs only)
Tag Number: 20 Characters
Process Output: Range in process units
Signal Output: Select type, signal range and (temperature only) error signal.
User offset: Enter sensor offset (Temperature mode only).
Active scaling: Set output process range against active sensor input

 

Environment
Operating Ambient: (-30 to 70) °C; (10 to 90) %RH (non-condensing)
Storage Ambient: (-30 to 70) °C; (10 to 90) %RH (non-condensing)
Configuration Ambient: (10 to 30) °C
Installation Enclosure: DIN Rail enclosure offering Protection >= IP65.

Approvals
CE: BS EN 61326


Mechanical
Style: DIN 43880
Colour: grey
Material: Polymide 6.6
Dimensions: width 17.5 mm; height 90 mm; depth 56.4 mm
Weight: < 70 grams
Terminals: 2.5 mm Maximum

 

 

Place Order(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/ Desc.
Qty
Description
  
TXDIN1600T
£124.78
Availability: In Stock
 
DIN Rail Mount Transmitter
  
TXDIN1600T-UKFS
Consult Sales  
Availability: 
 
 
DIN Rail Mount Transmitter scaled for specific input/output requirements (please specify in order comments)
Click to expand/minimize a list of what others bought with theUWTC-CABLE
UWTC-CABLE
£16.63
Availability: In Stock
 
USB Interface cable (required for connection to PC) mini Type B plug to Type A plug.
All amounts shown in EUR, GBP, or USD
We noticed you are from the US. Visit your local site for regional offers and live support.