Cookies on the OMEGA websites We use cookies on this website, these cookies are essential for the website to work correctly.If you continue without changing your settings, we'll assume that you are happy to receive all cookies on this website.To find out more information about these cookies please click here.
Application
• Linearized temperature measurement with TC and RTD sensors e.g. Pt100 and Ni100.
• HART communication and 4 to 20 mA analog PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors.
• Conversion of linear resistance to a standard analog current signal, e.g from valves or Ohmic level sensors.
• Amplification of bipolar mV signals to standard 4 to 20 mA current signals.
• Up to 63 transmitters (HART 7) can be connected in a multidrop communication setup. Technical Characteristics
• HART protocol revision can be changed by user configuration to either HART 5 or HART 7 protocol.
• The HART 7 protocol offers:
• Long Tag numbers of up to 32 characters.
• Enhanced Burst Mode and Event notification with time stamping.
• Device variable and status mapping to any dynamic variable PV, SV, TV or QV.
• Process signal trend measurement with logs and summary data.
• Automatic event notification with time stamps.
• Command aggregation for higher communication efficiency.
• TXUN-HT is designed according to strict safety requirements and is therefore suitable for applications in SIL installations.
• Continuous check of vital stored data. Meeting the NAMUR NE 21 recommendations, the TXUN-HT HART transmitter ensures top measurement performance in harsh EMC environments. Additionally, the TXUN-HT meets NAMUR NE43 and NE89 recommendations. Mounting/Installation
• For DIN form B sensor head mounting.
• Configuration via TXUN-KIT for standard set up or via HART programming unit for Hart Communication set up. See links in Notes.
Specifications Environmental Conditions Operating Temperature:-40 to 85°C Calibration Temperature: 20 to 28°C Relative Humidity: < 95% RH (non-cond.) Protection Degree (encl./terminal): IP68/IP00 Mechanical Specifications Dimensions: Ø 44 x 20.2 mm Weight Approx: 50 g Wire Size: 1 x 1.5 mm2 stranded wire Screw Terminal Torque: 0.4 Nm Vibration:IEC 60068-2-6 2 to 25 Hz: ±1.6 mm 25 to 100 Hz: ±4 g Common Specifications Supply Supply Voltage: 8.0 to 30 Vdc Isolation Voltage Isolation Voltage, Test/Working: 1.5 kVAC/50 Vac Response Time Response Time (Programmable): 1 to 60 s Voltage Drop: 8.0 Vdc Programming: Loop Link and HART Signal/Noise Ratio: > 60 dB Accuracy: Better than 0.05% of selected range Signal Dynamics, Input:, 22 bit Signal Dynamics, Output: 16 bit EMC Immunity Influence: < ±0.1% of span Extended EMC immunity: NAMUR NE21, A Criterion, Burst: < ±1% of span Input Specifications Common Input Specifications Max. Offset: 50% of selected max. value RTD Input RTD Type: Pt50/100/200/500/1000; Ni50/100/120/1000 Cable Resistance per Wire: 5 Ω (up to 50 Ω per wire is possible with reduced measurement accuracy) Sensor Current: Nom. 0.2 mA TC Input Thermocouple Type: B, E, J, K, L, N, R, S, T, U, W3, W5, LR Cold junction compensation (CJC): Constant, internal or external via a Pt100 or Ni100 sensor Voltage Input Measurement Range: -800 to 800 mV Min. Measurement Range (Span): 2.5 mV Input Resistance: 10 MΩ Output Specifications Current Output Signal Range: 4 to 20 mA Min. Signal Range: 16 mA Load (@ Current Output): ≤ (Vsupply - 8)/0.023 [Ω] Sensor Error Indication: Programmable 3.5 to 23 mA NAMUR NE43 Upscale/Downscale: 23 mA/3.5 mA Common Output Specifications Updating Time: 440 ms HART Protocol Revisions: HART 7 and HART 5 Observed Authority Requirements EMC: 2014/30/EU EAC: TR-CU 020/2011 Approvals ATEX 2014/34/EU: KEMA 03ATEX1537 IECEx: KEM 10.0083X FM: FM17US0013X CSA: 1125003 INMETRO:NCC 12.0844 X EAC Ex TR-CU 012/2011: RU C-DK.GB08.V.00410 DNV-GL Marine: Stand. f. Certific. No. 2.4 SIL: Hardware assessed for use in SIL applications