View the printable Thermocouple colorcode chart
(Printable version also contains international color codes)
All Omega Thermocouple Wire, Probes and Connectors are available with either ANSI or IEC color Codes. Please contact sales for instructions on how to order color-Coded products. More information about thermocouple wire.
ANSI Code |
Alloy Combination |
|
Maximum Useful Temperature Range ++ |
Maximum Thermocouple Grade Temperature Range |
EMF (mV) Over Max. Temperature Range |
Standard Limits of Error** (above O°C) |
Special Limits of Error** (above O°C) |
International IEC 584-3 |
Comments Environment — Bare Wire |
IEC Code |
||||
+ Lead | - Lead | Thermocouple Grade |
Extension Grade |
|||||||||||
J | IRON Fe (magnetic) |
CONSTANTAN COPPER-NICKEL Cu-Ni |
Thermocouple Grade: 32 to 1382°F 0 to 750°C Extension Grade: 32 to 392°F 0 to 200°C |
–346 to 2193°F –210 to 1200°C |
–8.095 to 69.553 |
greater of 2.2°C or 0.75% |
greater of 1.1°C or 0.4% |
Reducing, Vacuum, Inert. Limited Use in Oxidizing at High Temperatures. Not Recommended for Low Temperatures. |
J | |||||
K | CHROMEGA® NICKELCHROMIUM Ni-Cr |
ALOMEGA® NICKEL-ALUMINUM Ni-AI (magnetic) |
Thermocouple Grade: –328 to 2282°F –200 to 1250°C Extension Grade: 32 to 392°F 0 to 200°C |
–454 to 2501°F –270 to 1372°C |
–6.458 to 54.886 |
greater of 2.2°C or 0.75% |
greater of 1.1°C or 0.4% |
Clean Oxidizing and Inert. Limited Use in Vacuum or Reducing. Wide Temperature Range, Most Popular Calibration |
K | |||||
T | COPPER Cu |
CONSTANTAN COPPER-NICKEL Cu–Ni |
Thermocouple Grade: –328 to 662°F –250 to 350°C Extension Grade: –76 to 212°F –60 to 100°C |
–454 to 752°F –270 to 400°C |
–6.258 to 20.872 |
greater of 1.0°C or 0.75% |
greater of 0.5°C or 0.4% |
Mild Oxidizing, Reducing Vacuum or Inert. Good Where Moisture Is Present. Low Temperature and Cryogenic Applications |
T | |||||
E | CHROMEGA® NICKELCHROMIUM Ni-Cr |
CONSTANTAN COPPER-NICKEL Cu-Ni |
Thermocouple Grade: –328 to 1652°F –200 to 900°C Extension Grade: 32 to 392°F 0 to 200°C |
–454 to 1832°F –270 to 1000°C |
–9.835 to 76.373 |
greater of 1.7°C or 0.5% |
greater of 1.0°C or 0.4% |
Oxidizing or Inert. Limited Use in Vacuum or Reducing. Highest EMF Change Per Degree |
E | |||||
N | OMEGA-P® NICROSIL Ni-Cr-Si |
OMEGA-N® NISIL Ni-Si-Mg |
Thermocouple Grade: –450 to 2372°F –270 to 1300°C Extension Grade: 32 to 392°F 0 to 200°C |
–450 to 2372°F –270 to 1300°C |
–4.345 to 47.513 |
greater of 2.2°C or 0.75% |
greater of 1.1°C or 0.4% |
Alternative to Type K. More Stable at High Temps |
N | |||||
R | PLATINUM- 13% RHODIUM Pt-13% Rh |
PLATINUM Pt |
NONE ESTABLISHED |
Thermocouple Grade: 32 to 2642°F 0 to 1450°C Extension Grade: 32 to 300°F 0 to 150°C |
–58 to 3214°F –50 to 1768°C |
–0.226 to 21.101 |
greater of 1.5°C or 0.25% |
greater of 0.6°C or 0.1% |
Oxidizing or Inert. Do Not Insert in Metal Tubes. Beware of Contamination. High Temperature |
R | ||||
S | PLATINUM- 10% RHODIUM Pt-10% Rh |
PLATINUM Pt |
NONE ESTABLISHED |
Thermocouple Grade: 32 to 2642°F 0 to 1400°C Extension Grade: 32 to 300°F 0 to 150°C |
–58 to 3214°F –50 to 1768°C |
–0.236 to 18.693 |
greater of 1.5°C or 0.25% |
greater of 0.6°C or 0.1% |
Oxidizing or Inert. Do Not Insert in Metal Tubes. Beware of Contamination. High Temperature |
S | ||||
U | COPPER Cu |
COPPER-LOW NICKEL Cu-Ni |
NONE ESTABLISHED |
Extension Grade: 32 to 122°F 0 to 50°C |
Extension Grade Connecting Wire for R and S Thermocouples, Also Known as RX and SX Extension Wire. |
U | ||||||||
B | PLATINUM- 30% RHODIUM Pt-30% Rh |
PLATINUM- 6% RHODIUM Pt-6% Rh |
NONE ESTABLISHED |
Thermocouple Grade: 32 to 3092°F 0 to 1700°C Extension Grade: 32 to 212°F 0 to 100°C |
32 to 3308°F 0 to 1820°C |
0 to 13.820 | 0.5% over 800°C | NOT ESTABLISHED |
Oxidizing or Inert. Do Not Insert in Metal Tubes. Beware of Contamination. High Temperature. Common Use in Glass Industry |
B | ||||
G* (W) |
TUNGSTEN W |
TUNGSTEN- 26% RHENIUM W-26% Re |
NONE ESTABLISHED |
Thermocouple Grade: 32 to 4208°F 0 to 2320°C Extension Grade: 32 to 500°F 0 to 260°C |
32 to 4208°F 0 to 2320°C |
0 to 38.564 | greater of 4.5°C or 1.0% |
NOT ESTABLISHED |
Vacuum, Inert, Hydrogen. Beware of Embrittlement. Not Practical Below 399°C (750°F). Not for Oxidizing Atmosphere |
G (W) |
||||
C* (W5) |
TUNGSTEN- 5% RHENIUM W-5% Re |
TUNGSTEN- 26% RHENIUM W-26% Re |
NONE ESTABLISHED |
Thermocouple Grade: 32 to 4208°F 0 to 2320°C Extension Grade: 32 to 1600°F 0 to 870°C |
32 to 4208°F 0 to 2320°C |
0 to 37.066 | greater of 4.5°C or 1.0% |
NOT ESTABLISHED |
Vacuum, Inert, Hydrogen. Beware of Embrittlement. Not Practical Below 399°C (750°F) Not for Oxidizing Atmosphere |
C (W5) |
||||
D* (W3) |
TUNGSTEN- 3% RHENIUM W-3% Re |
TUNGSTEN- 25% RHENIUM W-25% Re |
NONE ESTABLISHED |
Thermocouple Grade: 32 to 4208°F 0 to 2320°C Extension Grade: 32 to 500°F 0 to 260°C |
32 to 4208°F 0 to 2320°C |
0 to 39.506 | greater of 4.5°C or 1.0% |
NOT ESTABLISHED |
Vacuum, Inert, Hydrogen. Beware of Embrittlement. Not Practical Below 399°C (750°F)–Not for Oxidizing Atmosphere |
D (W3) |
++ Except as further restricted by temperature limits for T/C diameter and insulation tables that follow. * Not official symbol or standard designation. ** For controlled initial accuracy below 0°C, ask OMEGA's sales Department for a CAL-4 calibration report. |